Comtrol RocketPort Plus Hardware Installation Download Page 5

RocketPort® Plus Hardware Installation

5 of 6

FCC Notices

Radio Frequency Interference (RFI) (FCC 15.105)
This equipment has been tested and found to comply with the
limits for Class A digital devices pursuant to Part 15 of the FCC
Rules.

This equipment generates, uses, and can radiate radio frequency
energy, and if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try and correct the interference
by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the distance between the equipment and receiver.

Connect the equipment to an outlet on a circuit different
from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for
help.

Labeling Requirements (FCC 15.19)
This equipment complies with Part 15 of FCC Rules. Operation is
subject to the following two conditions:

This device may not cause harmful interference, and

This device must accept any interference received, including
interference that may cause undesired operation.

Modifications (FCC 15.21)
Changes or modifications to this equipment not expressly
approved by Comtrol Corporation may void the user’s authority to
operate this equipment.

Serial Cables (FCC 15.27)
This equipment is certified for Class A operation when used with
shielded cables.

Troubleshooting and Running Diagnostics

The first step to troubleshooting a problem is to determine
that your RocketPort is functioning properly. To do so, you
can create a bootable diskette.

You need two files to create a bootable floppy diagnostic
diskette:

The

Rawrite

utility that creates a bootable diagnostics

diskette

The diskette image file (*.i).

You can find both files on the Comtrol Software and
Documentation CD 
or

download

them from the ftp site.

Note: If you have the Comtrol Software and

Documentation CD, you can use the Quick Start
Card for procedures for your operating system.

Creating a Bootable Diagnostics Diskette

This discussion outlines how to create a bootable
diagnostics diskette. You can use our Web site

ftp://

ftp.comtrol.com/bootdiag.htm

to:

Download the necessary files.

Easily find specific procedures for your operating
system to create the bootable diskette.

Diagnostics Overview

After you create a bootable diagnostic diskette, you can use
the diagnostic program to:

Confirm that the hardware is functioning.

Determine resolutions to conflicts during installation.

Provide you with the ability to stress test the cards.

For example, you may want to run the diagnostics
overnight to evaluate a possible problem. You will need
loopback plugs for each port that you want to stress test. If
you need additional loopback plugs, you can use the
appropriate Building Loopback Plugs discussion in this
document to build additional loopback plugs.

Running the Diagnostics

You can run the diagnostics using one of the following
methods:

Execute the

rocket.exe

file on the diskette in a native

DOS environment.

Note: The diagnostic occasionally fails when running in

Windows MS-DOS

®

windows.

Boot the system from diagnostics diskette you created.

Use the following procedure to run the diagnostics:

1.

Restart your machine in DOS mode or insert the
diagnostics diskette.

2.

Execute

rocket.exe

or start the machine.

The diagnostic starts automatically,

3.

Verify that the system locates the RocketPort card.

4.

Follow the remainder of the on-line instructions.

If the diagnostics did not pass you may want to use the
following discussion to diagnose your problem.

Mean time between

failures (MTBF)
Qcta/Quad
2 Port

17.9 Years

101 Years

Power consumption

Qcta/Quad
2 Port

5.79 W
1.89 W

RocketPort cards/system

4

Surge protection

Octa/Quad
2 Port

Provides ESD surge

protection exceeding:

25 KV
15 KV

Weight

Octa/Quad
2 Port

1 lb 10 oz. (with cable)

12 oz.

RocketPort Plus Card

Specification

Summary of Contents for RocketPort Plus

Page 1: ...ility to be 8 port cards with an 8 port interface Some drivers view the 4 port as an 8 port card All RocketPort Plus series interfaces support RS 232 You can install up to four RocketPort Plus cards in one PC for a total of 32 additional serial ports and you can install a combination of PCI bus and ISA bus RocketPort cards For driver installation see the software installation and configuration doc...

Page 2: ...ter installing the hardware you must install the device driver for your operating system Note If you are installing PCI and ISA RocketPort cards install the PCI cards and driver before installing and configuring the ISA cards See the software installation and configuration documentation or the driver readme file for information Use the following procedure to install the card 1 For the 2 port SMPTE...

Page 3: ...back plugs are used with the diagnostics to test serial ports This loopback is used with Quadcable Octacable and the Surge interface boxes Wire the following pins together for an RS 232 plug Pins 2 to 3 Pins 4 to 5 to 22 Pins 6 to 8 to 20 Wire the following pins together for an RS 422 loopback plug Surge interface box Pins 15 to 19 Pins 17 to 25 Pin DB9 Male RS 232 Signal DB9 Female SMPTE DTE DB9 ...

Page 4: ...ity non condensing System on System off 8 to 80 20 to 80 Altitude 0 to 10 000 feet Electromagnetic Compliance Status Emission Octa Quad only Canadian EMC requirements CISPR 22 EN55022 Class A FCC PART 15 Class A Yes Emission 2 Port only Canadian EMC requirements CISPR 22 EN55022 Class B FCC PART 15 Class B Yes Immunity Octa Quad and 2 Port EN50082 2 1995 IEC 1000 4 2 1995 IEC 1000 4 4 1995 IEC 100...

Page 5: ...ette image file i You can find both files on the Comtrol Software and Documentation CD or download them from the ftp site Note If you have the Comtrol Software and Documentation CD you can use the Quick Start Card for procedures for your operating system Creating a Bootable Diagnostics Diskette This discussion outlines how to create a bootable diagnostics diskette You can use our Web site ftp ftp ...

Page 6: ...herein may be the trademarks of their respective owners Comtrol Corporation makes no representations or warranties with regard to the contents of this reference card or to the suitability of any Comtrol product for any particular purpose Specifications subject to change without notice Some software or features may not be available at the time of publication Contact your reseller for current produc...

Reviews: