RocketPort® 485 Hardware Installation Card

4 of 8

Interface box

DB25 Interfaces

Use the following subsections for DB25 interface 
connectors. The Quad- and Octacable DB25 fanouts use 
DB25 male connectors.

Note: Although the RocketPort 485 card supports eight 

ports, if you have a quadcable connected, you will 
only have four ports available for use.

DB25 Pinouts

The following table and figure illustrates the DB25 
connectors:

Depending on jumper configuration, the pins carry the 
following values:  

*

Ports 1 and 2 can be either RS-232 or RS-485, while 
Ports 3 through 8 are RS-232 only. All RS-232 modem 
control signals are present in RS-485 mode, but not 
used.

** Ports 3 - 8 can be configured to carry +5V on Pin 22.

Do not use the +5V power option with the Quad/
Octacable. Using this feature with interfaces 
other than the DB9 box may result in 
unacceptable voltage loss.

Building DB25 Female Loopback Plugs or Cables

To perform loopback 
testing of DB25 ports in 
RS-232 mode, obtain or 
create a female DB25 
connector with the 
following pins wired 
together:

Pins 2 to 3

Pins 4 to 5 to 22

Pins 6 to 8 to 20

Note: (The connector illustrated is the standard DB25F 

supplied by Comtrol for use with RS-232/422 
interfaces.)

To test DB25 ports in RS-485 mode, obtain two female 
DB25 connectors and create the cable shown below:

Pin

RS-232 Signal

RS-485 Signal

1

Not used

Not used

2

TxD

TRX+

3

RxD

TRX-

4

RTS

Not used*

5

CTS

Not used*

6

DSR

Not used*

7

Signal ground

Signal ground

8

DCD

Not used*

9-19

Not used

Not used

20

DTR

Not used*

21

Not used

Not used

22

**

**

23-25

Not used

Not used

Pin 14

Pin 25

Pin 1

Pin 13

Caution

Pin 13

Pin 1

RS-232 Only (Back View)

Pin 25

Pin 14

Pin 13

Pin 1

Pin 14

Pin 25

RS-485 (Back View)

Pin 13

Pin 1

Pin 14

Pin 25

Pin 2 (TRX+)

Pin 3 (TRX-)

Summary of Contents for RocketPort 485 Series

Page 1: ...gy For the purposes of the following discussions these products are referred to as RocketPort ISA cards RocketPort ISA bus boards any interface type including 4J 8J Quadcable and Octacable RocketPort 485 These products are referred to as RocketPort PCI cards RocketPort PCI bus boards any interface type including 4J Quadcable and Octacable RocketPort Plus RocketPort PCI 422 Before Installing the Ha...

Page 2: ...efore installing and configuring the ISA cards See the RocketPort Software Installation and Configuration Guide or driver readme file for information 2 To use RS 485 on Ports 1 and 2 move all six pins on the port you want to use RS 485 to the left and center position When all six pins are in the center and right positions the port is configured for RS 232 Note In addition you must configure the po...

Page 3: ...xample you may want to run the diagnostics overnight to evaluate a possible problem You will need loopback plugs for each port that you want to stress test If you need additional loopback plugs you can use the appropriate Building Loopback Plugs discussion later in this Card to build additional loopback plugs Use the following procedure to run the diagnostics 1 Insert the Diagnostics diskette 2 Bo...

Page 4: ... this feature with interfaces other than the DB9 box may result in unacceptable voltage loss Building DB25 Female Loopback Plugs or Cables To perform loopback testing of DB25 ports in RS 232 mode obtain or create a female DB25 connector with the following pins wired together Pins 2 to 3 Pins 4 to 5 to 22 Pins 6 to 8 to 20 Note The connector illustrated is the standard DB25F supplied by Comtrol for...

Page 5: ...r disconnect the power supply cable before running the diagnostics If you do not do so the diagnostics fail To test DB9 ports in RS 485 mode obtain two female DB9 connectors and create a cable with the following wiring RJ45 Interfaces The Octacable RJ45 fanouts use RJ45 connectors RJ45 Pinouts The RocketPort 485 uses RJ45 connectors with the pins numbered as shown below Depending on jumper configu...

Page 6: ...w Note 2 for the second card then set the DIP switches on the third card the same as the switches on the first card EXCEPT SWITCH 6 OFF 4 If installing four ISA cards follow Notes 2 and 3 for the second and third cards then set the DIP switches on the fourth card the same as on the first card EXCEPT SWITCHES 5 AND 6 OFF Specifications The following tables illustrate RocketPort conditions and speci...

Page 7: ...nce and This device must accept any interference received including interference that may cause undesired operation Modifications FCC 15 21 Changes or modifications to this equipment not expressly approved by Comtrol Corporation may void the user s authority to operate this equipment Serial Cables FCC 15 27 This equipment is certified for Class A operation when used with shielded cables RocketPort...

Page 8: ...vailable to help you Before you call please have the following information available First Edition August 17 1999 Copyright 1999 Comtrol Corporation All Rights Reserved RocketPort is a registered trademark of the Comtrol Corporation Other product and company names mentioned herein may be the trademarks of their ...

Reviews: