DeviceMaster LT User Guide
: 2000586
Rev. B
Hardware Installation - 11
Hardware Installation
Use the following procedure to install the DeviceMaster LT 16-port with an
external power supply.
1.
Record the MAC address and serial number of the DeviceMaster LT unit on
the customer service label provided.
You may need the MAC address during driver configuration. The serial
number and MAC address (starts with
00 C0 4E
) are located on a label on the
DeviceMaster LT.
Note:
Do not connect multiple units until you have changed the default IP
address, see
2.
Place the DeviceMaster LT on a stable surface.
3.
Connect the DeviceMaster LT to the same Ethernet network segment as the
host PC using either port labeled
10/100
using
a standard Ethernet cable.
Do not connect RS-422/485 devices until the appropriate port interface
type has been configured. The default port setting is RS-232.
4.
Apply power to the DeviceMaster LT by connecting the AC power adapter to
the DeviceMaster LT, the power cord to the power adapter, and plugging the
power cord into a power source. See
External Power Supply Specifications
Page 109 if you want to provide your own power supply.
5.
Verify that the
STAT
LED has completed the boot cycle and network
connection for the DeviceMaster LT is functioning properly.
Note:
The RX/TX LEDs cycle during a reboot.
•
STAT
(Status LED) - If the Status LED on the DeviceMaster LT is lit, it
indicates the DeviceMaster LT has power and it has completed the boot
cycle.
The
STAT
LED flashes while booting and it takes approximately 15 seconds
for the Bootloader to complete the cycle. When the Bootloader completes
the cycle, the LED has a solid, steady light that blinks approximately every
10 seconds.
•
Ethernet LEDs - The green LED indicates that a link has been established
and the yellow LED indicates activity.
6.
Go to
on Page 13 for default network settings and how to
configure the DeviceMaster LT for use.
Caution