Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows):
2000472 Rev. C
5
Mounting the DeviceMaster 500
Mounting the
DeviceMaster 500
Use the following procedure to mount the DeviceMaster 500 1-Port embedded.
1.
Carefully remove the DeviceMaster 500 from the anti-static bag, following
standard electrostatic device handling procedures.
Note:
Write down the MAC address located on a label on the bottom (solder
side) center of the DeviceMaster 500 because you may need it during
configuration.
2.
Mount the DeviceMaster 500 for your environment using 1/4” stand-offs to
separate the DeviceMaster 500 from the base.
Non-plated/non-grounded mounting holes 0.116” diameter (+/-0.003”).
WARNING: Holes in hatched area are not mounting holes.
Maximum component height above board is 0.55”.
Ethernet connection J2: J2 overhangs board edge by 0.14” and the height is 0.55”.
LED light pipe mounting holes. The LED light pipes are not provided.
Serial port connector J3: 0.1” pin spacing, 0.025” square pin diameter, and 0.230”
pin height.
Debug port connector J4: 0.1” pin spacing, 0.025” square pin diameter, and 0.230”
Power connector; the mating connector is Weidmuller P/N: 1526510000
1
3
4
5
6
7
8
9
Plated/chassis grounded mounting hole 0.116” diameter (+/-0.003”).
2
pin height.
.