SLM-5650C / SLM-5650C-ODU Satellite Modem
Revision 1
Serial Remote Control
7–28
MN-SLM-5650C
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Number of
Unread
stored Events
N/A
3 bytes
Query only.
Unit returns the Number of stored Events, which remain Unread, in the
form xxx.
Note: This means unread over the remote control.
Example: NUE=126
N/A
NUE?
NUE=xxx
(see Description of Arguments)
Number of
Unread
stored
Statistics
N/A
3 bytes
Query only.
Unit returns the Number of stored Statistics, which remain Unread, in the
form xxx.
Note: This means unread over the remote control.
Example: NUS=126
N/A
NUS?
NUS=xxx
(see Description of Arguments)
BERT Pattern PAT=
1 byte
Command or Query.
BERT Pattern, where:
0=2047
1=Mark
2=Space
3=1:1
4=1:2
5=2^15-1
6=2^20-1
7=2^23-1
8=MIL-188
Example: PAT=0 (2047 Pattern)
PAT=
PAT?
PAT*
PAT#
PAT?
PAT=x
(see Description of Arguments)
Summary of Contents for SLM-5650C CyberLynx
Page 12: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Table of Contents TOC 10 BLANK PAGE ...
Page 36: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Introduction 1 18 MN SLM 5650C BLANK PAGE ...
Page 40: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Installation 2 4 MN SLM 5650C BLANK PAGE ...
Page 146: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Appendix A A 12 MN SLM 5650C BLANK PAGE ...
Page 162: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Appendix B B 16 MN SLM 5650C BLANK PAGE ...
Page 167: ......
Page 168: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...