Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–42
MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command
Query
Response to
Command
Response
to Query
External
Reference Mute
XRM=
XRM?
1 byte
numeric
Command or Query.
Sets or returns the external reference mute state in the form x, where:
0=Disable
1=Enable (SEE NOTE)
NOTE: To enable this command, the internal reference oscillator option must be
installed; otherwise, a mode error will result. A hardware mute condition generated
by the XRM mute is one of the conditions that can cause the MUT command to
return MUT=2. When enabled, the unit mutes when an external reference
oscillator is not detected.
EXAMPLE: <0001/XRM=1{CR}
XRM=
XRM?
MSK*
XRM=x