Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–34
MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command
Query
Response to
Command
Response
to Query
Retrieve Next 5
Unread Stored
Events
N/A
RNE?
75 bytes
Query only.
Returns the oldest 5 Stored Events that have not yet been read over the remote
interface, in the form {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body, where Sub-body is in the form ABCCddmmyyhhmmss:
A=Fault/clear indicator where F=Fault, C=Clear, I=Info
B=Fault type where 1=Unit, 2=RF, 3=Log
CC=Fault Code numbers, as in RAS? or Info Codes:
RAS FAULT CODES MAP AS FOLLOWS:
1)
P24V1
2)
P13VT
3)
A10V1
4)
A10VPS
5)
P5V8T
6)
P2V5T
7)
P1V2T
8)
N5V8T
9)
P7V8T
10)
FANR1
11)
FANR2
12)
ATEMP
13)
SHTDN
14)
IICST
15)
FWPWR
16)
CHKSM
17)
FPGAD
18)
BUCLD
19)
CHKSUM
20)
FPGAD
21)
BUCLD
22)
REFLD
23)
LNBCS
RNE=
RNE={CR}
ABCCddm
myyhhmms
s{CR}ABC
Cddmmyyh
hmmss{CR
}ABCCddm
myyhhmms
s{CR}ABC
Cddmmyyh
hmmss{CR
}ABCCddm
myyhhmms
s