DT4572 X-Band Down Converter
Rev. 0
Remote Control
MM/DT4572.IOM
57
B.6.2.2 A
TTENUATOR
The default is 10 dB.
Command
Details
Set Attenuator:
<DEV/ATT_ yy.yy'cr'
Confirmation: >DEV/ATT
_
yy.yy'cr'lf']
Retrieve Attenuator:
<DEV/ATT
_
'cr'
Confirmation: >DEV/ATT_
yy.yy'cr''lf']
Note:
yy.yy = 0.0 to 25.00 dB in 0.25 steps.
B.6.2.3 C
OLD
S
TART
The cold start function, if enabled, mutes the output signal for a predetermined time
following Power-Up to ensure a stable reference oscillator (15 minutes). The default is
OFF. This command is disabled in redundant systems (i.e. COMMAND NOT
AVAILABLE).
Command
Details
Set Cold Start:
<DEV/CLD
_
xxx'cr'
xxx = ON or OFF
Confirmation: >DEV/CLD
_
xxx'cr''lf']
Retrieve Status:
<DEV/CLD
_
'cr'
Confirmation: >DEV/CLD_xxx'cr''lf']
B.6.2.4 M
UTE
The default is ON.
Command
Details
Mute Output:
<DEV/MUT
_
xxx'cr'
xxx = ON or OFF
Confirmation: >DEV/MUT
_
xxx'cr''lf']
Retrieve Mute
Status:
<DEV/MUT
_
'cr'
Confirmation: >DEV/MUT_yyy'cr''lf']
yyy = ON/OFF/COLD
Summary of Contents for DT-4572
Page 2: ......
Page 4: ......
Page 6: ......
Page 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Page 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Page 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Page 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Page 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...