8.7.2.23
AID (Application Identification)
Use AID to create a “free form” message. The intent is to identify the satellite,
transponder, beam, destination or other aspects of the application that may be
significant to operations.
The message length corresponds to capability of the display (LCD or VFD). The
message may be up to 48 characters in total. Blanks must be used after line 1
information in order to space to line 2 – the second line begins at character 25. A
carriage return ends the command. Trailing blanks will be generated to fill the
display field. The AID display will alternate with the Equipment type display by
use of the clear function key on the front panel. The default is "AID MESSAGE".
Description
Details
Application ID:
<DEV/AID_xxxxxxx ... xxxxx{cr} where:
xxxxxxx ... xxxxx = Your message, maximum 48 characters.
Confirmation:
>DEV/AID_{cr}
xxxxxxxxxxxxxxxxxxxxxxxx{cr}
xxxxxxxxxxxxxxxxxxxxxxxx{cr}{lf}]
Return ID:
<DEV/AID_{cr}
Confirmation:
>DEV/AID_{cr}
xxxxxxxxxxxxxxxxxxxxxxxx{cr}
xxxxxxxxxxxxxxxxxxxxxxxx{cr}{lf}]
8.7.2.24
FRB (Force Reboot)
Use FRB to force the unit to reboot after five seconds.
Description
Details
Force Reboot:
<DEV/FRB_YES{cr}
Confirmation: