CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Front Panel Operation
MN-CDM750
5–17
5.2.2.1.4 (CONFIG) INTF: GBEIX
GBEIX: IntType FlowControl Learning
Where
X
designates
the
interface
as
GBEI
1
(
J5
|
DATA
port)
or
GBEI
2
(
J6
|
DATA
port):
Use
the
W
X
arrow
keys
to
select
IntType,
FlowControl
,
or
Learning
,
and
then
press
ENTER
.
(CONFIG: INTF) GBEIX
Æ
IntType
Take
care
in
using
this
menu,
as
a
mismatch
can
cause
random
packet
loss
and
connection
drops.
Interface Type:
Auto
To
configure
the
interface
type
of
the
selected
port:
On
the
bottom
line,
use
the
ST
arrow
keys
to
select
AUTO
,
1000
Base
‐
T
Full
Duplex
,
100
Base
‐
T
Full
Duplex
,
100
Base
‐
T
Half
Duplex
,
10
Base
‐
T
Full
Duplex
,
or
10
Base
‐
T
Half
Duplex
.
Press
ENTER
when
done.
Note
the
following:
External Equipment Capability
External Equipment Port Setting Correct Port Configuration Selection
on CDM750
10 Base-T, 10/100/ 1000 Base-T Auto
Auto
10 Base-T
Full Duplex
10 Base-T Full Duplex
10 Base-T
Half Duplex
10 Base-T Half Duplex
100 Base-T
Full Duplex
100 Base-T Full Duplex
100 Base-T
Half Duplex
100 Base-T Half Duplex
1000 Base-T (Gigabit)
Full Duplex
**
1000 Base-T Full Duplex
**
Forced
1000
Base
‐
T
Full
Duplex
is
a
non
‐
standard
mode
of
operation.
Comtech
EF
Data
strongly
recommends
that
you
ALWAYS
run
1000
Base
‐
T
(GbE)
ports
in
Auto
Negotiate
mode.
(CONFIG: INTF) GBEX
Æ
FlowControl
Flow Control: Disabled
Applies To All Ports
The
use
of
Flow
Control
or
Pause
Frames
is
useful
when
ALL
devices
connected
to
the
modems
are
set
to
honor
Pause
frames.
When
used
properly,
Flow
Control
can
act
as
a
traffic
valve
in
an
ACM
environment.
Summary of Contents for CDM-750
Page 76: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Updating Firmware MN CDM750 4 12 Notes...
Page 224: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix A MN CDM750 A 4 Notes...
Page 234: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix B MN CDM750 B 10 Notes...
Page 256: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix C MN CDM750 C 22 Notes...
Page 280: ...CDM 750 Advanced High Speed Trunking Modem Revision 2 Appendix D MN CDM750 D 24 Notes...
Page 300: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...