Timer Memory
This memory area is reserved for storage of [16] timers. These timers are user programmable. When
the CAT-250 is initialized, these timers are automatically loaded with default values.
Port #1 Timeout [*601*]
This timer limits the Port #1 transmission length. This timer is programmable between 60 and 1799
seconds. Example: To program the timer for 3 minutes, key-up and enter [*601*180]. Un-key and
the voice will say: "CONTROL OK." When initialize, this timer defaults to 180 seconds.
Port #2 Timeout [*602*]
This timer limits the Port #2 transmission length. This timer is programmable between 60 and 1799
seconds. Example: To program the timer for 3 minutes, key-up and enter [*602*180]. Un-key and
the voice will say: "CONTROL OK." When initialize, this timer defaults to 180 seconds.
System ID Timer [*603*]
This timer sets the time between transmissions of the repeater ID. The ID occurs when a repeater user
stops transmitting. This timer is programmable between 60 and 1799 seconds. The timer default is
480 seconds.
System Pending ID Timer [*604*]
The CAT-250 waits until the input is clear before generating a voice ID. If the System ID Timer expires
and the input is still not clear, the CAT-250 will wait an additional period of time before a forced ID is
sent. This timer sets the length of this period. This timer is programmable between 60 and 1799
seconds. The timer default is 120 seconds.
CRT and Programming Length Timer [*605*]
During the programming mode, this timer determines the maximum time the controller remains
unlocked. This timer is programmable between 60 and 1799 seconds. When initialize, this timer will
default to 600 second.
DTMF Access Sleep Timer [*606*]
This timer determines the time required for the repeater to be at rest before the DTMF access code is
required to activate the repeater. This timer is programmable between 60 and 1799 seconds. The
timer default is 60 seconds.
Link Auto Disconnect Timer [*607*]
During link operation if Zone 2 channel 6 is enabled the link will disconnect automatically after a period
inactivity. This timer is programmable between 60 and 1799 seconds. The timer default is 600
seconds.
Timed Message #1 Timer [*608*]
This timer sets the timed message repeat period. This timer is programmable between 60 and 1799
seconds. The timer default is 1799 seconds.