Computec
CDD5.0
EN
CDD 5.0: user manual – Rev.01
Page 7/63
1
Technical Specifications
1.1
Standards and Codes References
All the references to the standards and Codes are reported in paragraph 8.6 “Standard and codes
reference”.
1.2
Door Drive Data
Supply voltage
[100 ; 240]Vac 1-ph 50-60Hz, (115V – 20%, 230V + 30%)
Vac
Available Peak output power
300
VA
Nominal output power
200
VA
Working Temperature
[-10; +60]
°C
Humidity
[20;80] non condensing
%
Electrical protection
[5x20, 4A] rapid fuse on main power supply line
[5x20, 8A] fuse on the battery supply line
Environmental protection
IP-54 case
- Table 1: door drive data
1.3
Compatible Motors Data
Motor type
Nominal power
Nominal voltage
Nominal Current
GR 63x25 + SG80K (15:1) + Enc100
50VA
24V
2.7A
GR
63x55 + SG120 (15:1) +Enc100
100VA
24V
4.9A
SN40 (15:1) + IGO100/2
100VA
24V
4.9A
SN31 (15:1) + IGO100/2
100VA
24V
2.7A
SN 22,6 (7:1) + IGO100/2
50VA
24V
1.5A
Moog 1Nm (4:1 belt) + Enc500
100VA
24V
2.7A
Moog 2Nm (4:1 belt) + Enc500
200VA
24V
1.5A
- Table 2: compatible motors data
1.4
System mechanical data
Motor type
Moving mass limit
Maximum Parking
force available during
parking with door
opened
Maximum force
available during
closing movement
GR 63x25 + SG80K (15:1) + Enc100
180kg
70N
250N
GR
63x55 + SG120 (15:1) +Enc100
300kg
90N
270N
SN40 (15:1) + IGO100/2
300kg
85N
280N
SN31 (15:1) + IGO100/2
180kg
70N
240N
SN 22,6 (7:1) + IGO100/2
120kg
40N
200N
Moog 1Nm (4:1belt) + Enc500
180kg
150N
290N
Moog 2Nm (4:1 belt) + Enc500
300kg
150N
290N
- Table 3: system limits