Computec
CDD5.0
EN
CDD 5.0: user manual – Rev.01
Page 58/63
between panels.
with the external
handset access to “MLC
signal monitor” menu
(
), and check that
RVS output is active
(highlighted)
The RVS signal is not
active
Check the closing
force reversing
activates correctly.
Check the settings
of PC34 (5.3.2), if
PC34=2 note that
the RVS signal will
be active only for
0.5s. Repeat with
P34=0.
Check false
reversing
(execute this
test only in case
the door
reverses during
closing without
any obstacle)
20
From door open
condition apply a closing
command and check the
actual closing profile
-
Check if any friction
is present (dust
accumulated on the
sill, mechanical
settings on the
operator).
Go to step 21
21
Switch off the door drive
and check manually the
panels movement
Mechanical issues or
frictions are present
Fix mechanical issue,
remove the dust
from the sill. Repeat
step 20.
The panels movement is
free without any friction
Switch on the door
drive and check the
PC09 settings: if
necessary increase
the PC09 value and
repeat step 20.
- Table 28: functional check sequence -