Compaq DS10L - AlphaServer - 256 MB RAM Installation Instructions Download Page 1

© Compaq Computer Corporation 2000.

1

EK–DS10L–RM. B01

A

LPHA

S

ERVER

 DS10L

SINGLE BRACKET

RACKMOUNT INSTALLATION

Overview

 

Rackmount Guidelines

 

Unpack Rackmount Kit

 

Determine Base Zero

 

Mark and Prepare the Rails

 

Install the Brackets

 

Attach the Rackmount Ears

 

Insert and Secure the System

 

Check Power and Secure Cables

 

For More Information

WARNING:  To prevent injury, access is limited to persons

who have appropriate technical training and experience.

Such persons are expected to understand the hazards of

working within this equipment and take measures to

minimize danger to themselves or others.

Rackmount Guidelines

 

If you are installing four DS10L systems, see the

AlphaServer DS10L Quad-Bracket Rackmount
Installation

 (EK-DS10L-QM).

 

A maximum of eight DS10L systems may be
installed for each rackmount power distribution
unit.

H9A11

H9A10

H9A15

Number of DS10L systems

20

32

40

PDU and fan units needed

3

4

5

Unpack Rackmount Kit

The rackmount kit contains these instructions, two
brackets, U-clips and screws, two sets of threaded guide
pins (one set attached to the brackets and one spare set),
and two rackmount ears for securing the system in the
rack. (see Figure 1).

Figure 1  Unpacking the Rackmount Kit

PK2287

Determine Base Zero

Decide the relative position of the system in the rack.
Base zero is where the bottom of the system will be when
installed in the rack.

If your system is the first system in the rack,

 

then base

zero is between the first and second hole up from the floor
of the rackmount cabinet.

If you are adding your system to a rack already
populated

, then base zero is the top of the system

underneath the DS10L you are installing. Each DS10L
system height requires 1U (1.75 inches).

Mark and Prepare the Rails

 

Using the template on the back of this card (Figure
6), on both front rails and the rear interior rails,
mark base zero and hole 2 (see Figure 2).

 

If you are installing more than one AlphaServer
DS10L in the rack at the same time:

 using the

template, mark the top of the first system you are
installing.
Use this as base zero for the second system, move
the template up aligning with base zero, mark hole
2 and the top of this system, until you have marked
holes for each system you are installing.

 

Insert a U-clip at each rear interior hole you have
marked.

Figure 2  Marking Inner Rails

PK1033a-00

Base 0

Top

Guide Pin

1

3

2