D-4
POST Error Messages
Writer: Erica T B lakeney Project: Compaq Professional Workstation 5100 Reference Guide Comments: 299348-003
File Name: R-APPD.DOC Last Saved On: 3/12/98 12:30 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
POST Error Messages and Codes
continued
Error Code
Probable Source
of Problem
Action
601-Diskette
Controller Error
Diskette controller
circuitry
Contact your Compaq
authorized service provider.
605-Diskette
Drive Type Error
Mismatch in
drive type
Run Computer Setup or
Windows NT utilities.
611-Primary Floppy
Port Address Assign-
ment Conflict
Configuration error
Run Computer Setup or
Windows NT utilities.
612-Secondary
Floppy Port Address
Assignment Conflict
Configuration error
Run Computer Setup or
Windows NT utilities.
1151-System Board
COM Port 1 Address
Assignment Conflict
Configuration Error
Run Computer Setup
1152- System Board
COM Port 2 Address
Assignment Conflict
Configuration Error
Run Computer Setup
1155-COM Port
Address Assignment
Conflict
Both external and
internal serial ports.
Run Computer Setup or
Windows NT utilities.
1610-Temperature
violation detected
The system is too hot.
Turn off the workstation and
let it cool off. If the condition
persists, Run Diagnostics to
get more information; then
contact your Compaq
authorized service provider.
continued