Operation
4-7
Compaq Confidential – Need to Know Required
Writer:
Bob Young
Project:
Compaq StorageWorks SSL2000 Series Library Reference Guide
Comments:
Part Number:
187193-001
File Name:
e-ch4 Operation.doc
Last Saved On:
4/17/00 9:11 AM
Using the Escape Button to Access Status Mode
To enter the Status Mode, which displays all aspects of the Library’s
operating
and configuration status, press the
Escape
button at the Default screen. The
Library
remains online.
Table 4-3
Control Panel Button Functions
Display/Mode
Escape
Enter
π
θ
At POST Screen
N/A
N/A
N/A
At Default Screen
Enters Status
Mode
Enters Menu
Mode
Toggles between Page 1
and Page 2
In Status Mode
(while online)
Returns to
Default Screen
Same as in Menu
Mode
Same as in Menu Mode
In Menu Mode
Rejects Currently
Displayed Choice,
or
Aborts Control
Panel Operation
In Progress, or
Exits to Next
Higher Menu
Level, or
Exits Menu Mode
to Default Screen
Accepts Currently
Displayed Choice
Moves
υ
1 Line
Upward Through
List of Options, or
Scrolls Part of
Display 1 Line
Toward Top of
List of Options
Moves
υ
1 Line
Downward
Through List of
Options, or
Scrolls Part of
Display 1 Line
Toward Bottom of
List of Options
At Fault Screen
N/A
Clears Soft Errors
N/A
N/A
NOTE:
There is an auto-repeat feature for the
π
and
θ
buttons. When you press either
button for more than one-half second, the control panel behaves as if you were pressing
and releasing the button about four times per second. This effect stops when you release
the button.