Installation
A190-930TX_EN_03_ 2009-02-06
27
►
Remove plugs on the pressure inlet and outlet.
All piping must be free from any stress and tension whatever!
Pipes subject to stress may burst due to the load placed on them during
operation. This may cause damage to property and personal injury.
►
Use steel pipes to connect the dryer to the compressed air system.
The following figure shows an installation example.
Compressed air system
Item Component
1
Entry, humid air
2
Compressed air inlet
valve, owner end
3
Upstream filter, owner
end
4 Dryer
5 Downstream
filter
(option)
6
Compressed air outlet
valve, owner end
7
Outlet, dry air
8 Bypass
line
(option)
9
Valve in bypass line
(option)
10 Bypass filter (option)
11 Valve, outlet bypass
filter (option)
Example of an installation with bypass line
►
An upstream filter (3) ist to be installed. The connection lines for the
upstream filter (3) are to be installed at a slight incline in the direction of the
upstream filter.
►
One shutdown valve each (2, 6) is to be installed at the compressed air inlet
and outlet ends of the dryer.
►
If you fit a bypass line (8) with additional shutdown valve:
Fit the line such that, when carrying out maintenance work on the dryer, the
line system can continue to be supplied with compressed air.
Installing the electrical connection
Warning against electrical voltage
Only qualified specialist personnel may carry out work on the electrical
system!