To calibrate a BioBlend dispenser use the following procedure:
Refer to C4000 Master Manual for detailed instructions.
1.
Change the B configuration to b0000 as it will be set to inhibit standalone. (b1000 is
standard)
2.
Change the C config to be C00001
3.
Disconnect the communications from the FMS board or simply turn off the power switch
in the ComFutra head and then re-power the pump to put it into standalone mode
4.
Calibrate the Mineral side of the dispenser using the normal calibration procedures.
Refer to C4000 manual.
5.
Change the C Config to be C00002
6.
Calibrate the mineral side of the dispenser using normal calibration procedures
7.
Change the C Config to C00003 to enable the blend
8.
Check the Blend is set to 20% in the B config (b20)
9.
Do a couple of test fills and confirm you get a 20% blend. This can be done by filling a
20L pail and then checking after the fill that approx 4 litres of bio-fuel is shown in the
Litres display by using the Last Sale Value function of the Parameter menu.
10.
Change the B configuration back to b1000 to re-enable inhibit standalone, reconnect the
comms and turn on the ComFutra head.
11.
Wait a few minutes for the ComFutra to boot up then do a test fill or two using a card to
confirm that the dispenser is working correctly and you are still getting the correct blend
ratio.
Calibration Codes
NOTE:
All other C config codes are disabled.
Code
C = 00001
Calibration mode
–
Meter side A
C = 00002
Calibration mode
–
Meter side B
C = 00003
Blend mode
–
Both meters