![CommScope Ruckus ICX 7750 Hardware Installation Manual Download Page 77](http://html1.mh-extra.com/html/commscope/ruckus-icx-7750/ruckus-icx-7750_hardware-installation-manual_2643846077.webp)
Ruckus ICX 7750 Switch Hardware Installation Guide
75
Part Number: 53-1003900-10
Ruckus ICX 7750 Specifications
Power supply specifications (per PSU)
Power supply specifications (per PSU)
Power consumption (typical configuration)
All ports linked and up. 50% traffic with 64-byte packets. Fans at normal speed.
Airflow
ICX 7750-26Q:
Back-to-Front: Maximum. - 55 cfm, Typical - 25 cfm
Front-to-Back: Maximum. - 62 cfm, Typical - 29 cfm
ICX 7750-48F:
Back-to-Front: Maximum. - 55 cfm, Typical - 25 cfm
Front-to-Back: Maximum. - 61 cfm, Typical - 29 cfm
ICX 7750-48C:
Back-to-Front: Maximum. - 55 cfm, Typical - 32 cfm
Front-to-Back: Maximum. - 62 cfm, Typical - 36 cfm
N/A
Heat dissipation
Refere to the power consumption tables.
N/A
Power
supply
model
Maximum
output power
rating (DC)
Input voltage
Input line frequency
Maximum
input
current
Input line
protection
Maximum inrush current
RPS9
504 W
100-240 VAC (nominal)
100-264 VAC (range)
50/60 Hz (nominal)
47 – 63 Hz (range)
7 A
Line fused
30 A peak cold or warm start for <10
ms
10 A peak for cycles 10 ms – 150 ms
Less than fuse rating for >150 ms
RPS9DC
504 W
-48 VDC (nominal)
-40 to -60 VDC (range)
NA
15 A
-Ve fused
25 A peak cold or warm start for <10 ms
Less than 15 A after 150 ms
Model name
@100 VAC input
@200 VAC input
@-48 VDC input
Minimum number of
power supplies
Notes
ICX 7750-26Q
277 W
945 BTU/hr
274 W
935 BTU/hr
274 W
935 BTU/hr
1 AC or DC
Fan speed is at nominal.
ICX 7750-48F
254 W
867 BTU/hr
250 W
853 BTU/hr
250 W
853 BTU/h
1 AC or DC
Fan speed is at nominal.
ICX 7750-48C
510 W
1740 BTU/hr
511 W
1744 BTU/hr
511 W
1744 BTU/hr
1 AC or DC
Fan speed is at nominal.
Condition
Operational
Non-operational