TABLE 25 Cloud/On-premise-SmartZone management status LED
LED color
Status of hardware
Recommended action
Off (no light)
Switch is not connected to cloud/SmartZone management platform, or
cloud/SmartZone management has been disabled on the switch.
None.
Flashing green
Switch is attempting to connect to a cloud/SmartZone management
platform.
None.
Steady green
Switch successfully connected to cloud/SmartZone management platform,
and is operational.
None.
Flashing amber
Switch is being configured by cloud/SmartZone management platform.
None.
Power Status (PWR1 and PWR2) LEDs
Refer to the following table to interpret the system power status (PWR1 and PWR2) LEDs.
TABLE 26 Power Status LEDs During Normal Operation
LED Color
Status of Hardware
Recommended Action
Off
No power.
•
Check if internal power supply is disconnected.
•
Check the connections between the device, the
power cord, and the wall outlet.
•
Contact Technical Support.
Steady green
Internal power supply is working normally.
None.
Steady amber
Internal power supply for the PoE ports has failed.
Contact Technical Support.
Interpreting Nonport-Side LEDs
The RUCKUS ICX 7550 contains the following LEDs on the rear panel:
•
Power supply LEDs: Two single-color status LEDs (green) on each installed power supply
•
Fan assembly LEDs: One bicolor status LED (green and amber) on each installed fan assembly
•
Management port (RJ-45) LEDs: One for link/activity and one for speed. Each of these LEDs is green.
NOTE
The external reference clock input is not included in the ICX 7550-24, ICX 7550-48, ICX 7550-24P, and ICX 7550-48P models.
Rear Panels
The ICX 7550 supports the following types of rear panels for the specified models:
Monitoring the Device
Interpreting Nonport-Side LEDs
RUCKUS ICX 7550 Switch Hardware Installation Guide
Part Number: 53-1005648-04
85
Summary of Contents for RUCKUS ICX 7550
Page 10: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 10 Part Number 53 1005648 04 ...
Page 54: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 54 Part Number 53 1005648 04 ...
Page 66: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 66 Part Number 53 1005648 04 ...
Page 76: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 76 Part Number 53 1005648 04 ...
Page 90: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 90 Part Number 53 1005648 04 ...
Page 102: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 102 Part Number 53 1005648 04 ...
Page 108: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 108 Part Number 53 1005648 04 ...
Page 114: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 114 Part Number 53 1005648 04 ...