5. Setting up the Web GUI
Page 34
MF0123A1F
_FCC
_uc Manual for PSR 700/800 MHz
5.
Setting up the Web GUI
NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHER INVOLVED PARTIES
This product incorporates field-programmable software. In order for the product to comply with the requirements in the Standard
for In-building 2-Way Emergency Radio Communication Enhancement Systems, UL 2524 certain programming features or
options must be limited to specific values or not used at all as indicated below.
Program feature or option
Permitted in UL 2524 (Y/N)
Possible settings
Settings permitted in UL 2524
Deactivate Alarms
N
Delay Alarms
Y
1, 5, 10, 60, 600,
1380 minutes
1 minute for all alarms
5, 10, 60, 600, 1380 minutes only for
donor antenna malfunction alarm
5.1. LAN Settings at Local PC
In order to have access to the Web GUI, the following network adapter settings need to
be set at the local PC. Setting a static IP address in the same address range (see below
192.168.1.5) is required:
Access the LAN settings of your local
Select
Internet Protocol Version 4
PC and click
Properties
:
(TCP/IPv4)
and click
Properties:
.
→
Enter the IP
address.
→
Click
OK
.