5. Low Power EU Maintenance
M0200AJA_ION-U_EU_L_17EP_17EP.docx
User’s Manual for ION
®
-U
Page 55
4. Use a #2 Phillips head or
slotted screwdriver to loosen
the 8 universal slot/Phillips
captive power supply screws
and carefully remove the
supply. The weight of the
power
supply
must
be
supported as you loosen the
screws to prevent damage to
the supply.
figure 5-3 8 EU power supply screws
5. Carefully remove the power
supply from the unit. Do not
attempt to support the weight
of the supply with the attached
input and output cables.
figure 5-4 EU power supply with cables
6. Locate
the
input
cable
connector for the power supply
on the right side of the supply.
7. Loosen the 3 Phillips head
terminal screws and remove
the connector.
figure 5-5 EU power supply input cable
Mains
connector
Loosen 8 universal
slot/Phillips screws
Summary of Contents for ION-U EU L 17EP/17EP
Page 1: ...ION U ION U EU L 17EP 17EP User s Manual M0200AJA ...
Page 66: ......