Mounting instructions
• This kit shall be installed by trained and qualified personnel only.
• Only use recommended tools when installing this kit.
• Do not install this kit on unstable walls or on surfaces which cannot support the weight of the
device.
• No water may penetrate into this kit. Therefore, make sure this kit is waterproof towards the wall.
• Make sure this kit is not subject to torsional forces (e.g. on uneven walls).
• Install the Intercom station with a distance of min. 150 mm (6 in) downwards to enable access to the
locking screws (Tx08).
• It is recommended to mount the optional Cat. crimp jack C-RJ45-MONT onto the open end of a
Cat. cable within a flush mount box and to connect the Cat. 6 cable.
Recommended mounting height and position
• Mount the upper edge of the Intercom station approx. 1,650 mm
(65 in) from the finished floor. Adapt the mounting height to the
individual needs.
• For a barrier-free accessibility, it is recommended to mount the
Intercom station with enough space to walls or corners.
• When mounting the Intercom station, pay attention to the cor-
rect camera angle in terms of accessibility, so that wheelchair
users and children can be detected by the camera:
110° (vertical) x 130° (horizontal)
Type: D-BZ-OD5-SH, Version: 1.1/0320
Commend International GmbH, Saalachstraße 51, A-5020 Salzburg – www.commend.com
Extent of supply
• Surface mount kit (incl. tamper
switch)
• 4 mounting screws
• 4 dowels
• Cat. 6 cable (0.3 m/11.8 in)
• Short reference
Mounting
OD5 SH
Surface mount kit for an OD5 TD.
Drill four holes in the wall (see “Dimensions”) and insert the supplied dowels or alternatively
prepare a standard double flush mount box for mounting.
Guide the required cables (Ethernet and USB cable, if needed) through one of the provided cable
entries (from bottom or rear).
Install the surface mount kit to the wall using the supplied mounting screws (the locking element
must be at the lower end).
If required, connect the tamper switch to a module with an input (e.g. IP Secure Connector or
EB2E3A-AUD). This input must be configured accordingly via the web interface of the OD5 TD (see
also manual “
OD5 TD
”).
Connect the cables. Observe the cable run.
Insert the Intercom station at the top of the surface mount kit.
Press the Intercom station with its lower end firmly onto the surface mount kit.
Turn the locking screw anti-clockwise down as far as it will go using the Tx08 screwdriver (included
in extent of supply of the OD5 TD). Check whether the lower end of the Intercom station is fixed on
the surface mount kit.
Manufacturer’s reference
For technical specifications, see the respective data sheet.
For the latest software and documentation, visit:
www.commend.com
Keep this description in safe custody.
Dimensions
Measuring units in mm (in), not to scale!
23
(0.91)
11
2)
(0.43)
60 (2.36)
1)
200 (7
.87)
1)
86 (3.39)
228 (8.98)
1)
Dimensions for wall holes
(ø 5 mm/0.2 in)
2)
OD5 TD