Mounting instructions
• This kit shall be installed by trained and qualified personnel only.
• Avoid exposing the OD10 TD to direct sunlight when installed.
• Install the Intercom station with a distance of min. 150 mm (6 in) to walls and other objects to
enable access to the locking screws and to not mask the loudspeaker openings on the sides.
• Only use recommended tools when installing this kit.
• Do not install this kit on unstable walls or on surfaces, which cannot support the weight of the
device.
• No water may penetrate into the mounting box. Therefore, make sure the mounting box is water-
proof.
• It is recommended to mount the optional Ethernet socket RJ45-MONT onto the open end of a Cat.
cable within a flush mount box.
• Make sure this kit is not subject to torsional forces (e.g. on uneven walls).
Type: D-BZ-OD10-FB, Version: 1.3/0220
Commend International GmbH, Saalachstraße 51, A-5020 Salzburg – www.commend.com
Extent of supply
• Mounting box
• 5 cable ties
• Blind cover
• Short reference
Mounting
OD10 FB
Drywall/panel mount kit for an Intercom station OD10 TD.
Cut out the wall (see “Dimensions”).
Insert the mounting box onto the wall with the arrow pointing upwards.
Press the four claw clamps on the sides of the mounting box outwards and tighten them using the
corresponding screws (Tx10).
Pierce one of the provided cable glands depending on cable supply (from top, bottom or rear).
Guide the required cables through this entry (Ethernet, I/O and USB cable, if needed), run the cables
along the corners of the mounting box and adjust them to the desired length.
Assemble the Ethernet cable and connect it to the optional Ethernet socket. Insert the Ethernet
socket with its gib head on the right at the intended position and clip it on the left.
Fix the cables on the provided strain-relief using the cable ties included in extent of supply of the
OD10 TD.
Attach the blind cover included in extent of supply to the bottom side of the Intercom station using
a screwdriver (Tx10, not included in extent of supply).
Connect the cables to the Intercom station and the Ethernet socket (Ethernet, I/O and USB cable, if
needed).
Place the Intercom station on the mounting box so that the Intercom station attaches to every hook.
Press the Intercom station onto the mounting box and push it downwards to lock it.
Turn the two lateral locking screws clockwise out as far as it will go using the Tx08 screwdriver
(included in extent of supply of the OD10 TD). Check whether the Intercom station is fixed on the
mounting box.
Dimensions
Measuring units in mm (in), not to scale!
45
(1.77)
2 (0.08) to
25 (0.98)
3)
170 (6.69)
146 (5.75)
1)
304 (1
1.97)
1)
322 (1
2.68)
1)
Cut-out for wall mounting
2)
OD10 TD
3)
Wall thickness
18
(0.71)
2)
Recommended mounting height and position
• Mount the upper edge of the Intercom station approx. 1,650 mm
(65 in) from the finished floor. Adapt the mounting height to the
individual needs.
• For a barrier-free accessibility, it is recommended to mount the
Intercom station with enough space to walls or corners.
• When mounting the Intercom station, pay attention to the correct
camera angle in terms of accessibility, so that wheelchair users and
children can be detected by the camera.
NOTE: Wall mounting
• For mounting on brick walls,
additionally the flush mount
box OD10 FBS is required
(not included in extent
of supply). In this case,
plaster the flush mount box
OD10 FBS into the wall and
then continue with .
• To ensure that the tamper
detection functions cor-
rectly, the magnet in the
lower part of the mounting
box must not be covered,
damaged or electromagneti-
cally influenced.
• Due to the IP protection
class requirements, consid-
erable force may need to be
applied when pressing the
Intercom station onto the
mounting box.
Manufacturer’s reference
For technical specifications, see the respective data sheet.
For the latest software and documentation, visit:
www.commend.com
Keep this description in safe custody.