3. Assembly of components

GE 800

10

4.2/0617

Installation boards for GE 800

The plug-in cards can be used with the following installation boards:

Plug-in card

G8A-C

G8A-CP

G8A-I

G8A-K

G8A-T

G8A-V24 G8A-GEN G8A-NET G8A-TEL G8A-PRO G8A-EW

G8-16A

G8-16E

G8-8E8A

G8-CNET-E1

G8-LAN

X

G8-CNET-W

G8-AUD

*

*

G8-IAX

X

G8-IF

X

G8-IP / G8-IP-32

X

G8-TEL4

G8-GED

G8-GEN

G8-GEP

X

G8-GET

G8-NET

G8-S0

G8-SELCALL

G8-TEL

G8-V24-PRO

G8-VOIPSERV

X

*

When using the installation boards G8A-C or G8A-T the 4 relay contacts of the G8-AUD cannot be connected

Included in extent of supply

Available separately

X

Via Ethernet jacks of Intercom Server (G8A-NET)

Summary of Contents for GE 800

Page 1: ...GE 800 MANUAL VERSION 4 2 0617 PRODUCT MANUAL ENGLISH ...

Page 2: ...unctioning of the transmission path Attention This is a Class A product standard EN 55022 In a domestic environment this product may cause radio interferences in which case the user may be required to take adequate measures Defective power cables of the transformer may not be repaired or changed In case of defective power ca bles the whole transformer must be changed Mounting and installation of t...

Page 3: ...rcom stations 13 Connection inputs and outputs 16 Connection of multiple GE 800 19 5 Configuration CCT 800 24 Configuration via IP or RS 232 24 Networking of housings 24 Start up of a networked system 25 General information 31 Expansion 31 Standard call numbers 31 Dynamic audio channel allocation 32 Technical data 33 Intercom Server basic housing GE 800 33 Power supply card G8 GEN 33 Processor car...

Page 4: ...h will allow an error free operation Also this box will warn you if a certain configuration option or entered value could lead to a malfunction of the application or a loss of data NOTE This information box serves multiple purposes It ranges from basic configuration tips to additional advices and comments on occasional settings and events GOOD TO KNOW This information box provides background knowl...

Page 5: ...unting of the hardware and start up of the Intercom Server subscriber inter faces and input output cards Information about the interface cards and Intercom stations can be found in the respective product manuals The following steps are required for start up Start up steps for the GE 800 Overview This manual is split into the following chapters 1 Extent of supply 2 Additional Components 3 Assembly ...

Page 6: ... for removing of installation boards Country specific power supply The desired transformer incl mounting set for DIN rail in TS 35 format can also be ordered separately Type Power supply C GE800 Without transformer C GE800EU Transformer 230 V Europe C GE800AU Transformer 230 V Australia C GE800UK Transformer 240 V UK C GE800US Transformer 120 V USA Type Power supply X PA7 230VEU Transformer 230 V ...

Page 7: ... as door openers or barriers via floating relay contacts depending on type Interface cards By means of interface cards external systems such as telephones PCs or mobile radios can be connected and integrated Connection and networking cards Via connection and networking cards it is possible to con nect the Intercom Server to LAN WAN TCP IP 2 wire lines ISDN multiplexer media converter or the public...

Page 8: ... with voltage switched off Plug in card GEN GEP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 NET max per housing G8 16A 1 14 G8 16E 14 G8 8E8A 1 14 G8 CNET E1 5 G8 LAN 7 G8 CNET W 5 G8 AUD 14 G8 IAX 14 G8 IF 14 G8 IP 14 G8 IP 32 14 G8 TEL4 2 2 G8 GED 14 G8 GEN 1 G8 GEP 1 G8 GET 14 G8 NET 1 G8 S0 7 G8 SELCALL 3 4 G8 TEL 14 G8 V24 PRO 14 G8 VOIPSERV 6 1 Max 100 outputs may be switched on at the same time 2 For ...

Page 9: ...ation boards Insert the plug in cards into the 19 housing from the front panel side and fix them with the attachment clips Mount the corresponding installation boards at the rear of the Intercom Server See the following illustration Installation of plug in cards and installation boards Installation boards Plug in cards Tool for removing of installation boards ...

Page 10: ... G8A TEL G8A PRO G8A EW G8 16A G8 16E G8 8E8A G8 CNET E1 G8 LAN X G8 CNET W G8 AUD G8 IAX X G8 IF X G8 IP G8 IP 32 X G8 TEL4 G8 GED G8 GEN G8 GEP X G8 GET G8 NET G8 S0 G8 SELCALL G8 TEL G8 V24 PRO G8 VOIPSERV X When using the installation boards G8A C or G8A T the 4 relay contacts of the G8 AUD cannot be connected Included in extent of supply Available separately X Via Ethernet jacks of Intercom S...

Page 11: ...GE 800 Connection Intercom Server Installation board G8A GEN Overview installation board G8A GEN G8A GEN 1 2 3 4 5 6 7 8 9 30V 24V AC 24V AC S1W S1W S2 S1 IN2 IN1 MU2 MU1 S2W S2W S1 S1 S2 S2 Music alarm input Floating contacts Grounding point for wrist strap grounding Programming socket parallel to G8 GEN Door opener e g Power supply Wiring outputs Grounding 1 GND Shield 2 TXD 3 RXD 4 NC 5 GND 6 N...

Page 12: ... out via the G8 NET card G8A NET installation board The G8 IP card is connected to the network switch via the RJ45 jacks UPLINK or DOWNLINK on the installation board G8A NET Connection from a GE 800 to a switch NOTE Configuration For further information about configuration see manual Intercom Server Configuration UPLINK DOWNLINK OUT GEV IN GEV VJGTPGV EQPƂIWTCVKQP QPPGEVKQP VQ PGVYQTM ECTFU 0 6 9 ...

Page 13: ...5 1 1 m 3 3 ft or ASK KAT5 5 5 m 16 4 ft of our selection should be used because these cables are not cross jointed A standard Intercom cable can be used between jack and Intercom station the cables that are delivered with each station are cross jointed Connection scheme patch panel NOTE Connection DSP subscriber card At DSP subscriber cards G8 GED only A and B are connected NC not connected GEAC ...

Page 14: ...tivate the connected power supply per subscriber the two jumpers next to the subscriber jack must be set to PWR ATTENTION Analogue Intercom stations It is not allowed to connect analogue Intercom stations when the power supply of the jacks is activated This would destroy the connected devices PWR A B NC NC NC NC PWR PWR STD PWR STD PWR STD PWR STD PWR STD PWR STD PWR STD PWR STD PWR 1st subscriber...

Page 15: ...er 1st A1 B1 C1 D1 2nd A2 B2 C2 D2 3rd A3 B3 C3 D3 subscriber whiteblue whiteyellow A1 blue brown B1 whiteblue whiteyellow C1 yellow black D1 subscriber 2nd subscriber whiteblue whitegreen A2 green blue B2 whiteblue whitegreen C2 brown yellow D2 subscriber 3rd subscriber whiteblue whitegreen A3 black green B3 whiteyellow whitegreen C3 blue brown D3 4th subscriber 4th subscriber whiteyellow A4 whit...

Page 16: ...S7 S1W S2W S3W S4W S5W S6W S7W S8W S8 S2 S1 S3 S4 IN2 IN4 IN6 IN1 IN3 IN5 IN7 IN8 NC NC NC NC NC Colour code Outputs Inputs S1W S1 S2W S2 S3W S3 S4W S4 S5W S5 S6W whitebrown S6 whiteblue whitegreen IN 1 blue blue IN 2 whiteblue whitegreen IN 3 yellow yellow IN 4 whiteblue whitegreen IN 5 green green IN 6 whiteblue whitegreen IN 7 brown brown IN 8 whiteblue whitegreen black whiteyellow blue blue wh...

Page 17: ...lue whitegreen black whiteyellow blue blue whiteyellow S7W yellow whiteyellow S8W green S8 whiteyellow brown whiteyellow black S1 S2 S3 S4 Internal cabling 5 m or 10 m cable 16 4 ft or 32 8 ft black Internal cabling Attention As the outputs S11 to S16 have a common root the equipment to be connected must have a common reference point S11 S12 S11 16W S1W S1 S1 S2 S3 S4 S5 S6 S7 S1 S2 S3 S4 S5 S6 S7...

Page 18: ...tegreen yellow yellow whiteblue whitegreen green green whiteblue whitegreen brown brown whiteblue whitegreen black whiteyellow blue blue whiteyellow IN13 yellow whiteyellow IN15 green IN16 whiteyellow brown whiteyellow black Connection 5 m or 10 m cable 16 4 ft or 32 8 ft black IN2 IN4 IN6 IN8 IN10 IN12 IN14 IN2 IN4 IN6 IN1 IN3 IN5 IN7 IN8 IN10 IN12 IN14 IN9 IN11 IN13 IN15 IN16 IN1 GEAK 700 IN4 IN...

Page 19: ...overy protocol To localise other GE 800 in the local network the following IP address range is reserved 231 255 x 233 to 231 255 x 239 x stands for the ID of the Intercom Server With switch Without switch If more than 20 servers shall be connected a switch is required max 105 GE 800 See the following illustration Up to 20 GE 800 can be connected in series directly via the G8 NET card no switch req...

Page 20: ...y Jitter max 50 ms 0 packet loss for perfect audio quality Bandwidth Example 40 MBit s equals 270 conversations between two segments when no other load is on the network Multiple GE 800 within a network NOTES Information to the bandwidth One conversation with a 16 kHz bandwidth requires a throughput of 146 kBit s A network with a capacity load of 100 MBit s has an advisable load of 40 MBit s There...

Page 21: ...ts on a G8A NET installation board of the G8 NET card the GE 800 can be connect ed to multiple GE 700 Intercom Servers Example 1 Connection example of GE 800 and GE 700 Intercom Servers without a switch Example 2 Connection example of GE 800 and GE 700 Intercom Servers with a switch ...

Page 22: ...or GE 700 GE 700 network cards must be upgraded to at least software version 5 2 Limitations for synchronous connections Works like Ring 2 GE 800 is always Clock Master If CNET W or CNET E1 networking is used in the GE 700 system the GE 800 may only be connected on one side of the network see illustration below Otherwise non synchronous connections must be used LAN WAN S0 When G8 CNET W or G8 CNET...

Page 23: ...ancy connection If one of the two cables cannot establish a connection to the switch e g due to a defect the connection automatically takes over via the second cable Scheme of a network redundancy NOTE Requirements for network redundancy For network redundancy the switch must support Rapid Spanning Tree Protocol RSTP functionality ...

Page 24: ...ing of housings With networking cards G8 NET up to 105 housings can be networked to a local system in which all fea tures of the GE 800 are available Additionally multiple locations can be networked via further network cards e g G8 LAN G8 S0 or G8 CNET E1 NOTES Configuration It is not recommended to use RS 232 to USB adapters For detailed information about the configuration of features see manual ...

Page 25: ...6 Connect the computer with any housing and receive the configuration of the Intercom Server in CCT 800 for further information see manual Intercom Server Configuration All cards are rec ognised automatically and the Intercom Server can be configured ATTENTION Changing automatic allocated calling numbers The standard calling numbers that are automatically allocated to the housings must be changed ...

Page 26: ...guration to the Intercom Server Further information about the sending process can be found in the manual Intercom Server Configuration Changing the server ID with CCT 800 Configuration CCT 800 To change the server ID of an Intercom Server with CCT 800 follow the instructions below 1 Go to Menu Intercom Server Initialize The following dialogue appears Dialogue Initialization 2 In the field Current ...

Page 27: ...241 2 10 10 2 1 10 10 2 241 3 10 10 3 1 10 10 3 241 Function Description Router IP address In this field enter the IP address of the router gateway via which the Intercom Servers communicate VLAN ID In this field enter a VLAN ID when the GE 800 is in a virtual network Enter this ID as decimal value 0 4095 0 and 4095 are reserved Address Conflict Detection By activating this checkbox the IP station...

Page 28: ...ishes a NET connection to the next Intercom Server Checkbox deactivated It is not possible to establish a NET connection to the network Activate the checkbox Allow packets between up and downlink to enable communication via the jacks Uplink or Downlink see example 3 Checkbox activated It is possible that two networks can establish a connection over the Uplink and Downlink jack Checkbox deactivated...

Page 29: ...4 has to be connected Example 3 It is possible to enable or lock the communication between two networks over the Uplink and Downlink jacks In this example both cases are described Configuration Intercom Server 1 Allow NET ARP for Uplink Allow NET ARP for Downlink Intercom Server 2 Allow NET ARP for Uplink Allow NET ARP for Downlink Intercom Server 3 Allow NET ARP for Uplink Allow NET ARP for Downl...

Page 30: ... jitter ad justment At a bad Internet connection or missing QoS mechanisms this can lead to a reduced speech quality If the speech transmission at the start of conversations is faulty the time in the drop down list Jitter Buffer Start Delay should be increased If speech quality is not good during conversations the checkbox No decrement of Jitter Buffer should be activated This prevents automatic r...

Page 31: ...e is allocated GEN GEP 1 2 3 4 5 6 7 8 9 1 0 11 1 2 13 14 NET GEN GEP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 NET 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 14 149 150 151 152 153 154 155 156 8 101 102 103 104 105 106 107 108 113 114 115 116 121 122 123 124 129 ...

Page 32: ...z 48 radio conferences at 3 5 kHz G8 NET to G7 GEV 28 conversations between GE 800 and GE 700 G8 CNET E1 10 conversations in each mode G8 CNET W Depending on configuration 2 to 12 conversations in each mode NOTE Maximum number of radio conferences A maximum of 48 radio conferences can be configured NOTES Maximum number of LAN conversations For details regarding the number of max LAN conversations ...

Page 33: ...4 x 9 02 in Weight incl package approx 5800 g 12 8 lbs Mounting 19 3 HE Relay outputs max switching capacity 60 W respectively 125 VA max switching current 2 A max switching voltage 60 VDC 40 VAC Music input max 800 mVrms at 10 kW 16 kHz Inputs IN1 and IN2 for floating contacts max line resistance 1 5 kW Thermal dissipation loss for calculation of the thermal load 45 2 W Operating temperature rang...

Page 34: ...ccording DIN 41612 Power supply via Intercom Server Emergency power consumption see GE 800 above Dimensions 100 x 167 mm 3 9 x 6 6 in Weight approx 230 g 0 51 lbs Flash memory 8 MB RAM memory 2 MB Operating temperature range 0 C to 50 C 32 F to 122 F Storage temperature range 30 C to 60 C 22 F to 140 F Relative humidity 20 up to 80 not condensing Plug 165 pin connector Power supply via Intercom Se...

Page 35: ...E 800 with Programming jack 2 relay outputs 2 inputs for floating contacts Audio input Power switch G8 GEN power supply LED status indication power supply LED is on system power on LED is permanently off no power Indication power supply Main switch Intercom Server 45 HQT EQPƂIWTCVKQP Fuse 3 15 A UNQY DNQY ON OFF ...

Page 36: ... is permanently off no power or hardware fault LED is permanently on during reset or hardware fault LED blinks in rhythm definition error at least one wrong or missing plug in card Networking card G8 NET Fully digital networking card with 2 Ethernet ports and one digital data ring incl connection cable G8 NET networking card LED status indication RUN LED blinks in rhythm of one second the card is ...

Page 37: ...inks During logon and logoff of Intercom Servers LED status indication GEV LED is permanently off ring not in operation no clock received LED is permanently on ring in operation at least one further system is connected LED blinks fast there are the following possibilities Synchronisation and or data is not received correctly Cables are connected in an incorrect way Two housings with same number in...

Page 38: ...0B For further information as well as LED status indication see current manual G8 IP 32 DSP subscriber card G8 GED DSP subscriber card for connection of up to 4 digital subscribers via 2 wire lines A maximum of 14 G8 GED cards can be used in a GE 800 Intercom Server Per subscriber one conversation is possible si multaneously non blocking The card is available in the feature levels B C D and P Thes...

Page 39: ...to the main processor during initialising or reset LED blinks fast card inserted in wrong slot LED blinks in rhythm definition error wrong type of subscriber card LED status indication subscribers LED on a working Intercom station is connected LED off no Intercom station is connected LED blinks line fault LED flickers data are transmitted NOTE Status indication The LED status indication is only va...

Page 40: ...as make open or switch over contacts Input output card G8 8E8A Output card G8 16A Plug in card with 16 relay outputs 10 make contacts 6 as make contacts with common ground Output card G8 16A Status LEDs Input output card Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Status LEDs Output card Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 ...

Page 41: ...ED is permanently off no power or hardware fault LED is permanently on waiting for connection to the main processor during initialising or reset LED blinks fast card inserted in wrong slot LED status indication outputs LED is on output active LED is off output inactive LED status indication inputs LED is on input active LED is off input inactive Status LEDs Input card Input 1 Input 2 Input 3 Input...

Page 42: ... e g video switcher access control systems or host computers to Intercom Servers via IP networks or RS 232 using the Commend standard protocol Interface card G8 IF LED status indication RUN LED blinks in rhythm of one second the card is working correctly LED is permanently off no power or hardware fault LED is permanently on waiting for connection to the main processor during initialising or reset...

Page 43: ...GE 800 Technical Support 4 2 0617 43 Technical Support For more information about our products and services visit www commend com ...