Appendix
Control Station Duetto
170
1.7/1217
Add a new logic rule. See the following screenshot:
This logic rule opens a determined door
Select the
Event
“Digital input triggered”.
Select the
Digital input
which is connected to the external door opener switch.
Select
Trigger on
“Short“. The door open signal is transmitted on closed contact of the switch.
Select the
Action
“Open SIP Door” (Verweis auf S. 150) or “Open Intercom door“ (Verweis
138).
In the field
Open door from origin
, enter SIP-URI or Intercom call number from the desired door
station (e. g. “[email protected]:5060” or “121” ).
In the field
Door key
, select the door key 2.
Click on
APPLY
.
NOTE: Door opener works only with an established connection
To open the door a connection between door station and the DUETTO device has to be established.
The operator has to accept the call before he can use the door opener switch.
NOTE: Open door from origin
Following settings are possible:
Any
: The regarding door opener opens for any in the network connected station.
Intercom call number / SIP-URI
: The regarding door opener opens only for defined intercom call
number or SIP-URI.
1
1
2
2
2
Lorem ipsum
1
2
1
2