background image

IP Stations WS 201VICA/WS 211VICA

Connection diagram

160 (6.3)
140 (5.5)

275 (1

0.84)

255 (1

0.05)

4x 

Ø 

7

(0.28)

appro

x. 1

.65

 m 

(5.4 ft)

Finished floor

Dimensions and recommended mounting height

Measurements in mm (in), not scale! Front panel thickness: 3 mm (0.12 in)

OUT 2

OUT 2

OUT 2

OUT 2

OUT 1
OUT 1

EP+

EP–

EM+

EM–

MUTE

GND

LINE–

LINE+

IN 1
IN 2
IN 3
GND

external

loudspeaker

module

IP downlink

(Axis camera

 + PoE)

expansion bus

IP uplink 

+ PoE

LED brightness

+

handset:

microphone

loudspeaker

slot for inserting

button label

The camera illuminator and heating control are connected to the main board of the subscriber 

via the expansion bus. In CCT 800, the device is shown with an additional EB2E2A device. 

• Use OUT 1 on the EB2E2A to switch the camera illuminator on and off.

It is also possible to use OUT 1 as attendant contact, e.g. to switch on the camera illuminator

at call setup.

To dim the camera illuminator, use the potentiometer 

2

 on the camera board.

• Use OUT 2 on the EB2E2A to switch the camera heating on and off.

Camera illumination and heating control

1

1

2

Extent of supply

• Station

• Mounting screws (4 x Torx TR 25 security countersunk screws, M5 x 10)

• Snap-on ferrite (to be attached to IP uplink Ethernet cable)

• Short reference

Cleaning instructions

Safety instructions

The device may only be cleaned with cleaning agents for stainless steel. Do not use cleaning agents 

containing chlorine or isopropanol.

• This device shall be installed or replaced by trained and qualified personnel only.

• Do not install the device on unstable walls or on surfaces which cannot support the device’s weight.

• Only use recommended tools when installing the device.

• Only accessories that comply with the device’s technical specifications shall be used.

• All connected circuits shall fulfil the requirements for Safety Extra Low Voltage (SELV) and Limited

Power Source (LPS) according to IEC/EN 60950-1.

• Use shielded Ethernet cables only.

• Before using the device, ensure all cables are correctly connected and not damaged.

• Disconnect the power supply (PoE or DC) for any maintenance of the device.

• Allow the device to cool down completely before touching parts inside.

• Do not make any unauthorised modifications to the device.

Reviews: