background image

USER MANUAL

T20 Series

www.commax.com

Thank you for purchasing COMMAX products.
Please carefully read this User’

s Guide (in particular, precautions for safety) before using a product and

follow instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.

Summary of Contents for T20-C

Page 1: ...OMMAX products Please carefully read this User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly The company is not responsible for a...

Page 2: ...pe 4 User User Registration User Delete User Temporary ID 5 Setting Setting Basic Setting Advanced Setting Access Setting Communication Setting Event 6 USB Memory USB Memory 7 Information Memory Infor...

Page 3: ...Before Starting www commax com COMMAX Access Control Solutions...

Page 4: ...COMMAX Access Control Solutions Product Specification Confirm the specifications External Connector 1 25mm pitch T20 Series T20 F T20 D T20 C...

Page 5: ...or wet cloth when cleaning Use soft cloth Do not put around strong magnetic things such as TV monitor and magnet Call service centre if you have any problems Be careful not to drip liquid such as wat...

Page 6: ...COMMAX Access Control Solutions Components Bracket Cable Screw Programme CD TCP IP Extension Cable T 20...

Page 7: ...LCD Display time device status user list and UI LED Light on system status LED Light on system status Fingerprint Sensor Register and identify user s fingerprint Speaker Output sound effect voice mess...

Page 8: ...COMMAX Access Control Solutions Dimensions 48 mm 38 mm 34 4 mm 9 2 mm 138 mm 124 4 mm...

Page 9: ...rint Registration Proper way Improper way Note Register fingerprint Register fingerprint properly Recommend to register other finger part when a finger is wounded Recommend to register more than two f...

Page 10: ...COMMAX Access Control Solutions Verification Mode Verify set points on the menu Settings Advanced Operated Mode Card Fingerprint CARD...

Page 11: ...COMMAX Access Control Solutions Displays There is a display component of basic menu...

Page 12: ...COMMAX Access Control Solutions Ethernet Connection with Hub Ethernet Hub...

Page 13: ...COMMAX Access Control Solutions Ethernet Connection with PC KJ 3400 that is supported to automatic MDI MDIX can connect to PC through straight type but not cross type...

Page 14: ...Instruction of Card Type www commax com COMMAX Access Control Solutions...

Page 15: ...COMMAX Access Control Solutions Instruction of Card Type 1 File Excusion 1 Run Shortcut Tool exe of KJ 3400 2 Connect TCP IP to 3400 terminal port and PC...

Page 16: ...on 1 Search device 2 It can set communication parameter of installed product 3 It can register and delete master card 3 Device Search of Programme Explanation A 1 It can check equipment state no uniqu...

Page 17: ...ss Control Solutions Instruction of Card Type 4 Change IP Address and Port B 5 Register and Delete Master Card C 1 It can modify selected Denice ID Ip Address Subnet mask Default Gateway Port Number a...

Page 18: ...te only only one card at the device d Register Register only one card at the device e Get from device f Card type Select register or delete card 1 Register Delete Master Card It can flash LED of data...

Page 19: ...Instruction of Fingerprint Type www commax com COMMAX Access Control Solutions...

Page 20: ...ism implements menu button Press fingerprint sensor for 3 seconds and access to system menu If admin user registered only confirmed admin user has right to access to the system Note Dafult has no admi...

Page 21: ...Access Control Solutions Instruction of Fingerprint Type Default No admin user registered 1 Press fingerprint sensor for 3 seconds and access to system menu 2 Move between menus using navigator button...

Page 22: ...ns Instruction of Fingerprint Type 4 ID passwords and how to set up a user or administrator Use the arrows on the arrow on the sensor then press the OK button ID password can be up and down Then click...

Page 23: ...User www commax com COMMAX Access Control Solutions...

Page 24: ...COMMAX Access Control Solutions User Registration...

Page 25: ...ess OK button 3 Select Delete and press OK button 4 Input password USER ID to delete and press OK button 5 Select Fingerprint and or ID Card to delete If want to delete both fingerprint and card of th...

Page 26: ...ess to system menu 2 Select User and press OK button 3 Select Set Temp IP and press OK button 4 Input Temp ID Upto 8 digits and press OK button 5 Input access admission times Min 1 Max 9 with this the...

Page 27: ...Settings www commax com COMMAX Access Control Solutions...

Page 28: ...Time Set up the time of the device Device s time is applied to the time of the event So it is important the accurate time 2 Date Setup the date of the device 3 Date Format YYYY MM DD Define date form...

Page 29: ...s able to adjust the verification mode 2 ID mask When the user input ID it hides user ID as XXXXXX and enhance the security 3 Tamer Alarm When it detects tamper it activates alarm 4 Touch Sensor If to...

Page 30: ...ize the brightness When use this function it has to block external light 6 Factory Settings Reset all settings to the default 7 Clear General Log Delete all general log data 8 Clear Admin Log Delete a...

Page 31: ...P Card or Fingerprint only Not able to access even with the registered ID 4 OPEN Always Open Fail Safe Mode 5 CLOSE Always Closed Fail Secure Mode No access with any form of authorization 6 CD Card on...

Page 32: ...r Release Time Default 3sec Available to adjust between 1 99sec 4 Door Open warning Once door open if the door remains open over setting condition it activates alarm 5 Intrusion Sensor Intrusion fire...

Page 33: ...0minutes 8 Wiegand Format 26 34 35 37 64 Designate wiegand output format 26 34 35 37 or 64 Read all wiegand data regardless of wiegand settings 9 Anti Passback No Yes Anti passback activates through e...

Page 34: ...ice ID ranges between 1 999 When many devices are connected in one network each device must have unique address 2 TCP IP Settings 1 DHCP No Yes Choose DHCP on or off 2 IP Address 192 168 1 224 Setup I...

Page 35: ...6 Port 5005 Setup TCP Port 7 MAC Address Displays MAC Address of the device Cannot set it up from the device 8 Server Settings 7 1 IP Address Port 7 2 Port 7 3 Send Event 3 Com Password 0 8 Set the pa...

Page 36: ...Control Solutions Settings Log Settings 1 Admin Log Warning 0 100 If the management logo exceeds the setting value it alarms 2 General Log Warning 0 2000 If the management logo exceeds the setting va...

Page 37: ...USB Disk www commax com COMMAX Access Control Solutions...

Page 38: ...Download General log Download new general events 3 Download Admin log Download new management events 5 Download User Info Download user data 7 Upgrade Firmware Update Firmware File Name should be KJ...

Page 39: ...Information www commax com COMMAX Access Control Solutions...

Page 40: ...ser numbers which is enrolled in the device 2 Fingerprint Template numbers which is enrolled in the device 3 ID Card ID Card numbers which is enrolled in the device 4 General Log General log access ev...

Page 41: ...ce release date 3 Manufacturer Displays the device manufacturer 5 Product Type Displays the device Type 7 Firmware Version Displays the firmware version 2 Serial Number Displays the device serial numb...

Page 42: ...Installation Guide www commax com COMMAX Access Control Solutions...

Page 43: ...e CN501 Relay 1 2 Connect with door lock alarm device and etc CN503 Wiegand Input Connect with extension card reader CN506 Wiegand Output Output to set up card data CN505 Sensor Input Connect to exit...

Page 44: ...COMMAX Access Control Solutions Cable Connection T20 Connect DC12 Power supply to CN2 Doesn t matter the direction of the GND and VCC 6 Transfomer DV12V AC220V GND VCC...

Page 45: ...Connection TCP IP T20 It can build access control system by LAN or WAN without limited distance if uses TCP IP way It can connect RJ45 of opposite after connecting CN1 using enclosed extension cable S...

Page 46: ...or fingerprint reader but not controller if it connects with other main controller At this time it can use wiegand out socket CN503 when information that has hands over to main controller 12V GND WIG...

Page 47: ...ection RF Card Reader T20 It can connect cable of card reader that is set CON4 if connects with RF card reader Above picture shows connecting with KP 10 KP 20 CON4 Reader ex KP 10 Red 12V Black GND Gr...

Page 48: ...c sliding door and related equipment It is to connect cable from door contact sensor exit button and infrared sensor like above picture CON2 Sliding Door EXIT BUTTON Invasion Sensor or Fire Alram Door...

Page 49: ...hod that is installed various sensors read various situations related with various equipment as above picture It is operated equipment from various electric strikes or alarms connecting to CON4 RELAY...

Page 50: ...5 RS422 T 20 T20 RS485 RS485 Connect 1 and 4 RS485 Connect 2 and 3 RS485 It can be 422communication to connect 4 pins all 3 1 7 4 5 6 2 1 2 3 4 A B Z Y A B Z Y RS 485 Communication Cable Connection RS...

Page 51: ......

Reviews: