Comfort Home IDS Series Installation And Operating Instructions Download Page 1

1. HANDLING

2. APPLICATIONS

3. OPERATION RESTRICTION

4. INSTALLATION

5. ELECTRICAL CONNECTION 

6. MAINTENANCE

 7. SAFETY INSTRUCTIONS

The product must be lifted and handled the handle or the eyebolt 
carefully.

The pump is suitable for the transfer of clean, dirty or turbid liquids. 

With suspended solids not exceeding the dimensions indicated below. 

The most common application are drainage of domestic wastewater 

collection tanks, of rainwater collection tanks, of flooded rooms, of 

excavations and trenches in the building industry.

WARNING :

 Don’t allow the use of the pump in tanks or 

swimming pools while people are in the water. and requires 
the use of the  cable version for external applications.

WARNING:

Incorrect adjustments may cause malfunctions.

WARNING : 

The pump should be serviced by qualified 

technician, and after having been disconnected from the 
power mains.

 ● 

Fluid temperature :

    <

35

 (IVS); 

50

 (IDS)

 ● 

When operating continuously the pumps must be submersed 

    completely, with the exception of the IDS models.

 ● 

Maximum immersion depth : 

    5m for IVS series, and 7m for IDS series.

(FIG.2)

(FIG.1)

(FIG.3)

The float is adjusted by increasing or decreasing the free length of the 
cable. (FIG.3)

SINGLE-PHASE TYPE: insert the plug in a standard power socket.

THREE-PHASE TYPE (FIG.4):

5.1 Direction of rotation 

(only for three-phase type)

The proper rotation direction 

is clockwise when looking 

down the pump from above. 

Check by observing the pump 

performance.

(FIG.4)

The pump does not need any routine maintenance. It may occasionally 

be necessary to clean the suction screen (IDS) or the impeller. To 

enter the impeller on models equipped with a screen, loosen the 

screws that fasten the screen. 

(FIG.1)The well dimensions must be such as to prevent an 
unreasonable number of starts per hour. (FIG.2)

  1. The pump is not suitable for working with flammable or dangerous 

      liquids.

  2. Do not allow the power supply cable to lift or move the pump.
  3. Do not allow the pump to run dry or work out of the water.

  4. As the pump can start and stop automatically, never insert your 
      hands or other objects in it while it is connected to the power supply.
  5. The power plug and capacitor bracket must never be submerged.

  6. Pay attention to the working limits. Incorrect use may damage the 
      pump and other property. and hurt people. 

  7. Make sure that the rated voltage matches the voltage supply.
  8. If the pump is a three-phase model ,make sure that the mains 
      connection and grounding are performed by qualified electrician.

  9. As additional protection from lethal electric shock. Install a high 
      sensitivity switch.

10. Make sure that unauthorized persons do not allow to access to 
      the pump.
11. Disconnect the electric pump, or unplug it before removing it or 

      carrying out any maintenance operations.
12. Use the pump only within the specified limits shown on the rating 

      nameplate.
13. Evade icing.
14. Protect the pump from block.

3~

L1

L2

L3

ON

OFF

100mm

=>

45

°

90

°

1 m

min

PIECE CONNECTOR

CHECK VALVE

GATE VALVE

FLOAT SWITCH

IDS75(A)

8

8

8

8

35

50

50

50

IDS100(A)

IDS150(A)

IVS75(A)

IVS100(A)

IVS150(A)

IDS200

IVS200

Pass Solids [mm]

NOTE: The single –phase electric pumps are fitted with a built-in 

automatic reset thermal protection.

Reviews: