1. HANDLING
2. APPLICATIONS
3. OPERATION RESTRICTION
4. INSTALLATION
5. ELECTRICAL CONNECTION
6. MAINTENANCE
7. SAFETY INSTRUCTIONS
The product must be lifted and handled the handle or the eyebolt
carefully.
The pump is suitable for the transfer of clean, dirty or turbid liquids.
With suspended solids not exceeding the dimensions indicated below.
The most common application are drainage of domestic wastewater
collection tanks, of rainwater collection tanks, of flooded rooms, of
excavations and trenches in the building industry.
WARNING :
Don’t allow the use of the pump in tanks or
swimming pools while people are in the water. and requires
the use of the cable version for external applications.
WARNING:
Incorrect adjustments may cause malfunctions.
WARNING :
The pump should be serviced by qualified
technician, and after having been disconnected from the
power mains.
●
Fluid temperature :
<
35
℃
(IVS);
<
50
℃
(IDS)
●
When operating continuously the pumps must be submersed
completely, with the exception of the IDS models.
●
Maximum immersion depth :
5m for IVS series, and 7m for IDS series.
(FIG.2)
(FIG.1)
(FIG.3)
The float is adjusted by increasing or decreasing the free length of the
cable. (FIG.3)
SINGLE-PHASE TYPE: insert the plug in a standard power socket.
THREE-PHASE TYPE (FIG.4):
5.1 Direction of rotation
(only for three-phase type)
The proper rotation direction
is clockwise when looking
down the pump from above.
Check by observing the pump
performance.
(FIG.4)
The pump does not need any routine maintenance. It may occasionally
be necessary to clean the suction screen (IDS) or the impeller. To
enter the impeller on models equipped with a screen, loosen the
screws that fasten the screen.
(FIG.1)The well dimensions must be such as to prevent an
unreasonable number of starts per hour. (FIG.2)
1. The pump is not suitable for working with flammable or dangerous
liquids.
2. Do not allow the power supply cable to lift or move the pump.
3. Do not allow the pump to run dry or work out of the water.
4. As the pump can start and stop automatically, never insert your
hands or other objects in it while it is connected to the power supply.
5. The power plug and capacitor bracket must never be submerged.
6. Pay attention to the working limits. Incorrect use may damage the
pump and other property. and hurt people.
7. Make sure that the rated voltage matches the voltage supply.
8. If the pump is a three-phase model ,make sure that the mains
connection and grounding are performed by qualified electrician.
9. As additional protection from lethal electric shock. Install a high
sensitivity switch.
10. Make sure that unauthorized persons do not allow to access to
the pump.
11. Disconnect the electric pump, or unplug it before removing it or
carrying out any maintenance operations.
12. Use the pump only within the specified limits shown on the rating
nameplate.
13. Evade icing.
14. Protect the pump from block.
3~
L1
L2
L3
ON
OFF
100mm
=>
45
°
90
°
1 m
min
PIECE CONNECTOR
CHECK VALVE
GATE VALVE
FLOAT SWITCH
IDS75(A)
8
8
8
8
35
50
50
50
IDS100(A)
IDS150(A)
IVS75(A)
IVS100(A)
IVS150(A)
IDS200
IVS200
Pass Solids [mm]
NOTE: The single –phase electric pumps are fitted with a built-in
automatic reset thermal protection.