background image

For more information, visit www.fmiproducts.com

SAVE THIS BOOK

This  book  is  valuable.  In  addition  to  instructing  you 
on how to install and maintain your appliance, it also 
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep 
it with your other important papers.

This fireplace is approved for use as a wood burning fire-
place or for use with a vented gas log approved to ANS 
Z21.60, Z21.84 standards or for use with a vent-free gas log 
heater approved to ANS Z21.11.2 standard. A FMI PROD-
UCTS, LLC hood must be installed when using a vent-free 
log heater (see 

Accessories

, page 18).

This  wood  burning  fireplace  complies  with  UL127-
CAN/ULC-S610-M87  standard  as  a  FACTORY  BUILT 
APPLIANCE.

FOR CANADA: The authority having jurisdiction (such 
as the municipal building department, fire department, 
etc.) should be contacted before installation to deter-
mine the need to obtain a permit.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Wood burning Fireplace

oWner’S operaTion and inSTallaTion Manual

Model b36l-M

ICC-ES #ESR-2542

PFS

®

US

C

Flame

Flame

TM

Comfort

Comfort

by FMI PRODUCTS, LLC

Summary of Contents for B36L-M

Page 1: ...heater approved to ANS Z21 11 2 standard A FMI PROD UCTS LLC hood must be installed when using a vent free log heater see Accessories page 18 This wood burning fireplace complies with UL127 CAN ULC S...

Page 2: ...ydamageor loss of life Refer to this manual for assistance or additional in formation Consult a qualified installer or local distributor IMPORTANT Check local codes before installing this fireplace Be...

Page 3: ...125 0 TO BOTTOM OUTSIDE AIR LEFT SIDE ONLY TOP SPACERS 0 75 AIR SPACE BACK AND SIDES HEARTH EXTENSION 52 X 16 12 EACH SIDE NOT LESS THAN 14 TO PERPENDICULAR SIDEWALL 1 AIRSPACE TO COMBUSTIBLE COMBUSTI...

Page 4: ...ure ment includes fireplace chimney sections and height of termination assembly at level of flue gas outlet see Figure 18 page 11 Framing 1 Frame opening for fireplace using dimen sions shown in Figur...

Page 5: ...obtained from manufacturer or supplier of noncombustible material If hearth extension is to be covered use noncombustible mate rial such as tile slate brick concrete metal glass marble stone etc Provi...

Page 6: ...ing Fireplace 6 Ref 6 Min 33 3 Nom Note Drawing Not To Scale Safe Zone For Projection of Combustible Materials Combustible Material 12 Min 9 Min Fireplace Opening Top of Louvered Opening Fan Blower Ki...

Page 7: ...t Hood Required for Wall Installation Air Inlet Eyebrow Vented Crawl Space Check Local Codes Before Installing in a Vented Crawl Space Venting Installation Optional Outside air Kit Model AK4 AK4F Inst...

Page 8: ...be obstructed Never use blown insulation to fill chimney enclosure Continue to assemble chimney sections as outlined making sure that both inner and outer pipe sections are locked together When instal...

Page 9: ...60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1 2 2 1 64 3 4 120 3 4 2 1 68...

Page 10: ...ing to prevent leakage through screw holes A roof coating must also be ap plied around perimeter of flashing to provide a proper seal Firestop Spacers V3600FS 8DM 1 Firestop spacers are required at ea...

Page 11: ...ermination being used Flashing Cone Venting Installation Continued Attach Bracket Tabs to Outer Pipe 3 Places Secure with Screws RTL 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingle...

Page 12: ...t contact with sides and top around fireplace face It is important that combustible materials do not overlap face itself Brick glass tile or other noncombustible materials may overlap front face provi...

Page 13: ...line and refractory knockout hole with refractory cement or commercial furnace cement Install gas appliance or cap off gas line if desired CAUTION Allgaspipingand connections must be tested for leaks...

Page 14: ...lass Doors Glass doors are optional with this fireplace When fireplace is in operation doors must be fully opened or fully closed position only or a fire hazard may be created see Figure 23 A fireplac...

Page 15: ...ill lock door closed WARNING Risk of fire Re placegratewithFMIPRODUCTS LLC model 109910 01 only This gratehasbeendesignedtokeep the operation of your fireplace safe and efficient Technical Service You...

Page 16: ...www fmiproducts com 115385 01D 16 Parts Wood burning Fireplace MODEL B36L M 11 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 21...

Page 17: ...6970 01 Right Side Brick Liner 1 14 106972 01 Bottom Brick Liner 1 15 106973 01 Front Bottom Brick Liner 1 16 21198 Blower Access Plate 1 17 20027 Refractory Retainer 2 18 Top Insulation 1 19 Insulati...

Page 18: ...I DRAFT SHIELD Round Top Termination Only ADS 8DM 30 Offset and return 30E 8DM 30E HT Adjustable Hood Antique Brass Finish GA6053 Black Painted Finish GA6050 Required when installing a vent free gas l...

Page 19: ...rminations with Slip Section RTT 8DM RTTL 8DM RTT 8HT RLTT 8HT Outside Air Kit for Side Wall Installation AK4 Outside Air Kit for Floor Installation AK4F Square Chase Top Termination ET 8DM ET 8DM ET...

Page 20: ...115385 01 Rev D 06 10 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com...

Reviews: