background image

 

COMET SYSTEM

, s.r.o., Bezrucova  2901 

 

Specifications are subject to change without notice. 

756 61 Roznov pod Radhostem, Czech Republic

 

 

  ie-lgr-U8415-01

 

 

CO

2

 

monitor

 

U8415

 

 

 

DESCRIPTION AND USE 

 

Battery  powered  device 

U8415

  with  external  power  possibility  is  designed  to  indication  of  CO

concentration  inside  buildings  (schools, 

conference halls, hospitals, offices, cinemas, theaters, 

…). The level of CO

2

 concentration is indicated by the device using three colors (LED 

diode in the upper left corner), changes in the indicated states are also signaled acoustically - by a beep. The signaling method can be set by 

the user using th

COMET Vision

 software, see below for a description - section "

Setting of the device parameters

". 

 

The device U8415 is equipped with a maintenance-free and long-term stable NDIR sensor with dual wavelength and multi-point calibration. 

 

TECHNICAL PARAMETERS 

1) 

Settings can be changed using COMET Vision software

 

2) 

Recommended interval under normal operating conditions 

 

INSTALLATION AND USAGE OF THE DEVICE: 

 

The device can be switched on/off manually by pressing the ON/OFF button on the device 
or  by  using  the 

COMET  Vision

  software.  It  is  available  free  of  charge  at 

https://www.cometsystem.com/products/comet-vision-analytical-software-for-

dataloggers-and-multiloggers/reg-cv

 and can be used to device control and configuration. 

After switching  On

 the device performs an initial test for  approx. 20 s: if the internal 

On/Off timer is NOT activated in the device configuration (default factory setting) a beep 

sounds once. If 

the internal On/Off Timer is configured to use 

and the device follows 

that time program 

a beep sounds twice

. Subsequently, twice flashes all colors in order 

green, orange, red, first slowly and secondly faster. Then 3s pause follows, then 

for 3s

 

the

 

color that indicates the battery status lights

the battery 

is charged

 

sufficiently

 (more than 50%) 

it is 

advisable

 

to charge the

 battery (20 - 50 %) 

the  battery 

must  be  charged

  (less  than  20%),  otherwise  the  battery  may  be 

permanently damaged due to deep discharge. 

The device is delivered from the manufacturer with a fully charged battery (part of the device). 

DEVICE DIMENSIONS 

 

 

OPTICAL AND ACOUSTIC SIGNALING 

 

LED flashing when the device is 

switched Off and external power is connected (battery charging) 

via the USB-C connector: 

 

 

 

 

 

 

 

 

 

 

 

The battery is fully charged. 

 

 

 

 

 

 

 

 

 

 

 

Finishing charging (charged more than 90%). 

 

 

 

 

 

 

 

 

 

 

 

Full power charging is in progress. 

 

 

 

 

 

 

 

 

 

 

 

The battery is too low (this may affect battery life), next time charge it earlier. Charging will take longer time. 

 

 

 

 

 

 

 

 

 

 

 

The battery may be damaged or discharged too deeply. Leave the device under supervision connected to 
an external power supply (charger), if the condition does not change after 2h, contact the supplier of the device. 

 

 

 

 

 

 

 

 

 

 

 

Charging is temporarily suspended 

due to low (below 0°C) or high (above 40°C) temperature of the device.

 

 

 

 

 

 

 

 

 

 

 

 

Charger reports an error, check the power adapter, or contact the supplier. 

1  2  3  4  5  6  7  8  9  10  11 

 

 time t [s] 

Power supply: 

internal battery and external USB-C 5V/1A for 
battery charging/power 

CO

2

 measurement interval: 

15 s with external power supply,  
2 min on battery power

1) 

CO

2

 concentration accuracy: 

±

(50 ppm + 3 % from measured value) 

Recommended calibration interval: 

5 years 

2) 

CO

2

 concentration measuring range: 

0 to 5000 ppm 

Operating temperature range: 

-20 to 

+60 °C

 

Operating humidity range: 

5 to 95 %RH (no condensation) 

Operating pressure range: 

700 to 1100 hPa 

Storage temperature: 

-20 to 

+60 °C

 

Storage humidity: 

5 to 95 %RH (no condensation) 

Storage pressure: 

700 to 1100 hPa 

Protection class: 

IP 30 

EMC: 

EN 61326-1 

Weight: 

approx. 250 g 

MOUNTING AND CONNECTION 

The CO

2

 monitor U8415 is equipped with 

a pair of holes for screwing to the wall, its 
mounting position is shown in the figure. 
For device mounting it is possible to use 
LP100  -  lockable  datalogger  holder  for 
wall  mounting,  for  magnetic  surfaces 

holder  LP103,  for  easy  installation  self-
adhesive  Dual  lock  MD036 

  all  as 

optional accessories. 
Device  is  equipped  with  a  rechargeable 
battery  -  prevent  it  from  being  deeply 

discharged, check its  condition regularly 
and charge it if necessary. 
The device can be connected to external 

power using the supplied power adapter 
with a USB-C connector. 
We recommend verifying the measurement 
accuracy of the device by regular calibration.

 

Reviews: