Comet System H5021 Instruction Manual Download Page 4

 

 

IE-HGS-H5(6)0XX-05 

1.  General description 

The regulators are designed for online measurement of temperature (°C or °F), relative humidity 

and carbon dioxide concentration of air without aggressive ingredients. Measured temperature and 
relative humidity are recomputed to following humidity expression: dew point temperature, absolute 
humidity, specific humidity, mixing ratio and specific enthalpy. 

 

 

Type 

Temperature 

Humidity 

CO

2

 

Computed value 

H5021 

 

H5024 

 

H6020 

 

 

 

 

 

The device is equipped with two relay outputs for alarming or controlling of external devices. It is 

possible to assign any input value to each relay, to set comparing limit, delay, hysteresis and acoustic 
alarm.  

Measured and computed values are optionally shown on dual line LCD display. If there are two 

values displayed at one LCD line, they are periodically switched between both readings with period 
of 4 seconds. Display can be switched OFF totally too. On the left LCD side there are placed three 
LEDs for CO

2

 zone level indication.  

 
 
 
 

2.  Regulator mounting and connection 

Regulators  are  designed  for  wall  mounting.  Device  must  be  mounted  on  the  plane  surface  to 

prevent its deformation. Mounting holes and connection terminals are accessible after demounting of 
four screws in the corners of the box and removing the lid. There is recommended to use screws with 
half round head with cross-recessed screw ST 3.9 (DIN 7981). Unpack external probe for measuring 
the concentration of CO2 and connect to the device. 

 Lace the lead-in cable with outer diameter of 3 to 6.5 mm through the glands at the case wall and 

connect  them  according  schematic  below.  Terminals  are  self-clamping  and  can  be  opened  by 
a suitable  screwdriver.  For  the  opening,  insert 
the  screwdriver  to  smaller  terminal  hole  and 
lever  by  him.  Do  not  forget  to  tighten  glands 
and case lid with inserted packing after cables 
connecting.  Insert  attached  plug  into  unused 
cable glands too. Do not connect the regulator 
under voltage. 

It  is  not  recommended  to  use  the  H6020 

regulator  for  long  time  under  condensation 
conditions. It could be the cause of water steam 
condensation  inside  the  sensor’s  cover  into 
water  phase.  This  liquid  phase  stays  inside 
sensor’s cover and can’t escape from the cover 
easily.  It  can  dramatically  increase  response 
time  to  relative  humidity  change.  If  water 
condensation occurs for longer time it can cause 
sensor damage. Similar effect can occur under 
water aerosol conditions. 

 

Electrical system (wiring) may be done only by a worker with required qualification by rules in 

operation. 

Summary of Contents for H5021

Page 1: ...CO2 concentration temperature humidity and other calculated humidity variables regulator with two relay outputs H5021 H5024 H6020 Instruction Manual...

Page 2: ...etting with using regulator keys 10 5 5 3 Extended setting mode 10 5 6 Restore to Factory default measurement part 14 6 ERROR STATES OF THE DEVICE 14 7 READINGS ON LCD DISPLAY 15 8 PREVENTIVE MAINTENA...

Page 3: ...evice connection please Models marked HxxxxZ are non standard versions of the devices Description is not included in this manual Copyright COMET System Ltd It is prohibited to copy and edit this instr...

Page 4: ...connection terminals are accessible after demounting of four screws in the corners of the box and removing the lid There is recommended to use screws with half round head with cross recessed screw ST...

Page 5: ...IE HGS H5 6 0XX 05 5 3 Dimensions H5024 H6020...

Page 6: ...IE HGS H5 6 0XX 05 6 H5021 4 Device connection...

Page 7: ...upply voltage of the device you can use jumpers J1 and J2 for interconnection the power supply of the device directly with the common contacts of the relays This modification is used in devices with s...

Page 8: ...d then Relay2 setting step by step Information about Relay1 are indicated with symbol for Relay2 with symbol at right top corner of LCD It is possible to edit parameters after pressing SET key and ent...

Page 9: ...ion of internal setting new setting is possible to write only while during write period press SET key do requested setting in TSensor software press SET key on regulator and keep it down then click on...

Page 10: ...nd changes are valid immediately after its storing it is NOT necessary to restart regulator 5 5 3 Extended setting mode During regulator operation it is possible to change only parameters described in...

Page 11: ...found then output relay stays unchanged in previous status Relay1 switch OFF Relay1 switch On stays unchanged in previous status Relay2 switch OFF Relay2 switch On Change of Password for setting thro...

Page 12: ...between green and yellow indication It means that if actual measured value is lower than YELL limit there is green LED active If actual measured value is higher than YELL limit then there is yellow LE...

Page 13: ...ing show value on LCD don t show value on LCD Show CO2 concentration at LCD display This item provides to choice if CO2 value may be displayed at LCD display or not It is possible to change it after S...

Page 14: ...is over upper limit of allowed full scale range There is a reading Err1 on LCD display Value read from the device is 999 9 This state appears in case of Measured temperature is higher than approximat...

Page 15: ...ncorrect writing procedure to device s memory occurred Error 9 inserted password is not valid there is shown for short time message Err9 on LCD display 7 Readings on LCD display C F reading next to th...

Page 16: ...125Vac 2A 60 W 62 5 VA EMC EN 61326 1 EN 55011 9 1 2 H5021 CO2 regulator Concentration of CO2 Accuracy 100 ppm 5 of measuring value at 25 C 77 F and 1013 hPa Range 0 to 10000 ppm Temperature dependen...

Page 17: ...50 C 32 to 122 F Long term stability typ 20 ppm year Resolution 1 ppm Measuring temperature and humidity range is limited in accordance with the graph below Response time measurement of temperature a...

Page 18: ...ew point temperature Range 60 to 80 C 76 to 176 F Accuracy 1 5 C 2 7 F at ambient temperature T 25 C 77 F and relative humidity RH 30 for more details see graphs below Absolute humidity Range 0 to 400...

Page 19: ...itch off the LCD display at ambient temperatures above 70 C 158 F around electronics Operating humidity range H5021 0 to 100 RH no condensation H5024 H6020 5 to 95 RH no condensation Operating pressur...

Page 20: ...5 to 95 RH no condensation atmospheric pressure 700 a 1100 hPa Dimensions see dimensional drawings Weight approximately H5021 1m probe 420 g H5021 2m probe 450 g H5021 4m probe 510 g H5024 330 g H6020...

Page 21: ...Connection of external power relay Coil data chart of external power relay nominal voltage max 50V nominal power max 60VA current max 2A 11 Appendix B Wiring diagram of relay contacts for devices wit...

Reviews: