background image

 

 

 

EN 

Possible hazards from machine use 

If kept in good conditions and if installed correctly (according to the indications in this 
manual), the equipment does not expose the user to any kind of hazards. 

 

 

Risks from electricity: direct contacts during its connection to the 
main power supply. 
Operations to be carried out by qualified personnel. 

Risks during installation and preparation of the device. 

Follow the installation instructions, in order to minimise risks to people and objects. 
 

 

Risks  from  electricity: 

direct  contacts  during  its  connection  to  the 

main  power  supply.  Operations  to  be  carried  out  by  qualified 
personnel.

 

 
Precautions : 

 

Make  sure  that  the  distribution  line  is  sized  according  to  the  intensity  of  the 
current absorbed by the equipment. 

 

Carry  out  the  earth  connection  before  connecting  equipment  or  aggregate 
devices. 

Risks during the maintenance of the device 

 

 

Risks  from  electricity:  direct  contact  with  live  parts  inside  the 
electrical components cabinet. 
Operations to be carried out by qualified personnel. 

 
Precautions : 

 

Operate  on  the  equipment  only  after  ensuring  that  the  main  power  switch  is 
turned OFF. 

 
 
 
 
 
 

Summary of Contents for RM5 HD

Page 1: ...EN R RM M5 5 H HD D Electronic Coin Validator Operating Manual Cod DMGEH00001 3 2EN Rel 1 3 2 27 10 2015...

Page 2: ......

Page 3: ...EN GUIDE TO THE SYMBOLS IN THIS MANUAL The following symbols have been included in this manual to facilitate its consultation Important information Read carefully before use Caution...

Page 4: ...IEC60950 1 2005 AMD1 2009 AMD2 2013 IEC60950 22 Gessate 04 06 2009 Riccardo Chionna CEO Comestero Group s r l SAFETY INFORMATION To prevent damages caused by short circuits and fires this device is e...

Page 5: ...s to people and objects Risks from electricity direct contacts during its connection to the main power supply Operations to be carried out by qualified personnel Precautions Make sure that the distrib...

Page 6: ...months This period starts from the date of purchase of the product The warranty is exclusively limited to the normal operation of the goods supplied and to the result of the service provided The warra...

Page 7: ...not authorized by us will render the warranty null and void We declare to have carefully considered to the best of our knowledge and manufacturing practices the issue related to preventing the goods...

Page 8: ...2002 unless agreed otherwise If the purchaser delays each benefit in the terms and conditions that may have been granted shall be deemed null and void and the seller may demand immediate payment of a...

Page 9: ...tor version with separator 19 E Connection of the Totalizer version 20 F Connection of the Totalizer version with separator 20 G Connection of the Virtual Dip Switch 21 H Connection to a PC 22 I CN3 U...

Page 10: ...ring an innovative design offers the highest performance in terms of recognising legal coins and detecting false ones The special design of the drop duct has allowed for a significant reduction of the...

Page 11: ...upture of the packaging wet or damp patches or signs which indicate that the package has been exposed to rain frost or heat signs of tampering Also make sure that the content of the packaging correspo...

Page 12: ...HD coin validators required a multiple unit 20 packaging Fig 2 or a single unit packaging Both packaging consist of corrugated cardboard The packaging materials contained in it are made to meet the s...

Page 13: ...information For an easy identification of the coin validator i e its configuration operation mode and calibration type of accepted coins please find below a graphic representation of the labels affixe...

Page 14: ...with a maximum diameter of 31 5 mm and a maximum thickness of 3 4 mm Each of these two versions is available in four different models in order to meet any installation requirement Model Coin inlet Co...

Page 15: ...ersion B Version G B Front panel RM5 HD is compatible with F1 and F6 front panels and can be mounted either on the front or the rear of any machine For details regarding installation follow the instru...

Page 16: ...RM5 HD Operating Manual 16 Fig 6 B 2 Front panel F6 Fig 7...

Page 17: ...ble in 3 versions ccTalk Giochi Italia and Full Validator and totalizer Follow carefully the instructions below to ensure a correct connection for these three versions A Connection of the cc Talk vers...

Page 18: ...sm to the machine CPU by means of the CN2 ccTalk connector and to the separator by means of CN1 SEP connector as shown below Fig 10 Below is the pin numbering for the interested connector Pin number M...

Page 19: ...ing 1 Gnd 6 Inhibition 2 Vcc 7 CH1 3 CH 5 8 CH 2 4 CH 6 9 CH 3 5 CH 7 10 CH 4 D Connection of the parallel validator version with separator In presence of a separator connect the RM5 HD coin mechanism...

Page 20: ...sm to the machine CPU by means of the CN1 SEP connector as shown below Fig 13 Below is the pin numbering for the interested connector Pin number Meaning Pin number Meaning 1 Gnd 6 Inhibition 2 Vcc 7 3...

Page 21: ...the coin counter and the credit can be redirected to any pin chosen by the user from 7 to 10 Standard factory settings are those set as Default G Connection of the Virtual Dip Switch Each RM5 HD elec...

Page 22: ...or Pin number Meaning Pin number Meaning 1 Gnd 4 RX 2 5 Vdc 5 N U 3 TX 6 N U H Connection to a PC RM5 HD can be connected to a PC by means of a CN2 ccTalk connector This connection allows configuring...

Page 23: ...nts Configuration allows for example carrying out operations such as self learning modifying dip switches or some operating parameters RM5 HD can be configured by means of the mobile Virtual Dip Switc...

Page 24: ...ng activating recognition of coins with hole c Teaching RM5 HD to recognise a false coin d Inhibiting activating the anti fraud devices with which RM5 HD is provided Starting up the Self test function...

Page 25: ...ally designed for the GAMING industry It consists in a high number of specific controls aiming at a considerable control flexibility of a control unit called Host Machine specifications It is designed...

Page 26: ...w The table below shows two different sets of controls for the ccTalk Giochi Italia and ccTalk other configurations Full versions Header Custom Control Gaming ITALIA Other Config 1 Reset device X X 2...

Page 27: ...X 238 Test output lines X X 240 Test solenoids X X 241 Request software revision X X 242 Request serial number X X 243 Request database version X X 244 Request product code X X 245 Request equipment...

Page 28: ...sensor failed cash reject 0x06 0xXX Diameter sensors error Data byte 1 is a bitmask reporting which diameter sensor failed By means of control 229 Read buffered credit or error codes the ccTalk versi...

Page 29: ...5 Vdc inhibition state Following the insertion of a coin the coin mechanism sends the warning signal to the machine which at this point can decide whether to accept the coin earthing PIN 6 validator i...

Page 30: ...to 15 different coin values i e up to 62 coins provided that they are redirected on the first 15 channels Channel 1 is used to indicate the type of communication to the machine If disabled open collec...

Page 31: ...or is installed is disconnected from the power supply We strongly recommend following these instructions carefully in order to always keep the validator in the best operating conditions and to prevent...

Page 32: ...ntained in the Spare parts manual 8 Diagnosis and technical assistance In this section are described the main anomalies that may occur using this product with the possible solutions to minimise or eli...

Page 33: ...00 Supply Voltage Vdc 12 24 10 Current consumption mA Stand by Max 70 In acceptance Max 400 Temperature range C 25 70 Not condensed humidity 10 75 Accepted coins dimension 16 25 Minimum mm 17 27 Maxim...

Page 34: ...an automatic cash or vending machine In summary This equipment is not to be disposed of as unsorted municipal waste but must be disposed of separately Dealers will pick up used equipment free of charg...

Page 35: ...for every machine released onto the market 4 Manufacturers who in EEE use instructions do not provide the information as in article 13 paragraph 1 will be fined between 200 and 5 000 Euros 5 Manufact...

Page 36: ...g the exceptions as in article 5 paragraph 2 anyone releasing EEE containing substances listed in article 5 paragraph 1 after the 1st of July 2006 will be fined between 50 and 500 Euros for each unit...

Page 37: ...37 EN...

Page 38: ...RM5 HD Operating Manual 38...

Page 39: ...39 EN...

Page 40: ...Comestero Group S r l Via Marie Curie 8 20060 Gessate MI Tel 39 02 95781111 Fax 39 02 95 380178 www comesterogroup com comestero comesterogroup it...