background image

 

 

35 

 

EN 

 

 
Sanctions in case of illegal disposal of such waste : 
 

1.

 

The  distributor  who  does  not  retrieve  the  used  electrical  or  electronic  equipment 
free of charge, as stated in art. 6, paragraph 1, letter b), will be fined between  150 
and 400 Euros, for every equipment unretrieved or retrieved not free of charge. 

2.

 

Manufacturers who fail to provide a separate professional EEE disposal system in 
compliance  with  article  6  –paragraph  3,  as  well  as  EEE  retrieval,  handling, 
treatment  and  recycling  systems  according  to  article  8  -  paragraph  1,  article  9  – 
paragraph 1, 11 – paragraphs 1 and 12 – paragraphs 1, 2 and 3, notwithstanding 
for  the  latter  operations,  agreements  concluded  in  compliance  with  article  12  – 
paragraph 6, will be fined between 30.000 and 100.000 Euro. 

3.

 

Any manufacturer who after the 13th August 2005 releases  electrical or electronic 
equipment without  financial guarantee  in compliance with article 11 – paragraph 2 
or  art.  12    -  paragraph  4,  will  be  fined  between  200  and  1,000  Euros    for  every 
machine released onto the market. 

4.

 

Manufacturers  who  in  EEE  use  instructions  do  not  provide  the  information  as  in  
article 13 – paragraph 1, will be fined between 200 and 5,000 Euros. 

5.

 

Manufacturers  who,  within  one  year  from  releasing    a  new  type  of    EEE  ,  do  not 
make  information  available  to  disposal/recycling  centres  according  to  article  13  – 
paragraph 3, will be fined between 5000 and 30,000 Euros. 

6.

 

Manufacturers  who,  after  the  13th  August  2005,  releases  EEE  without  the 
indications and symbols as in art. 13, paragraphs 4 and 5, are fined between 200 
and  1,000  Euros  for  each  equipment  released.  The  same  fine  is  charged  should 
the aforementioned indications and symbols are not conform to the requirements 
set by art. 13, paragraphs 4 and 5. 

7.

 

Manufacturers  who  releases  EEE  without  having  registered  with  the  chamber  of 
commerce  in  compliance  with  article  14  –  paragraph  2,  will  be  fined  between 
30,000 and 100,000 Euros. 

8.

 

Any manufacturer who, within the time limit established in article 13 – paragraph 8 
does not communicate to the national registry concerning the disposal of EEE as 
stated  in  article  13  –  paragraphs  3,  4  and  5    will  be  subjected  to  the  foreseen 
sanctions. 

Summary of Contents for RM5 HD

Page 1: ...EN R RM M5 5 H HD D Electronic Coin Validator Operating Manual Cod DMGEH00001 3 2EN Rel 1 3 2 27 10 2015...

Page 2: ......

Page 3: ...EN GUIDE TO THE SYMBOLS IN THIS MANUAL The following symbols have been included in this manual to facilitate its consultation Important information Read carefully before use Caution...

Page 4: ...IEC60950 1 2005 AMD1 2009 AMD2 2013 IEC60950 22 Gessate 04 06 2009 Riccardo Chionna CEO Comestero Group s r l SAFETY INFORMATION To prevent damages caused by short circuits and fires this device is e...

Page 5: ...s to people and objects Risks from electricity direct contacts during its connection to the main power supply Operations to be carried out by qualified personnel Precautions Make sure that the distrib...

Page 6: ...months This period starts from the date of purchase of the product The warranty is exclusively limited to the normal operation of the goods supplied and to the result of the service provided The warra...

Page 7: ...not authorized by us will render the warranty null and void We declare to have carefully considered to the best of our knowledge and manufacturing practices the issue related to preventing the goods...

Page 8: ...2002 unless agreed otherwise If the purchaser delays each benefit in the terms and conditions that may have been granted shall be deemed null and void and the seller may demand immediate payment of a...

Page 9: ...tor version with separator 19 E Connection of the Totalizer version 20 F Connection of the Totalizer version with separator 20 G Connection of the Virtual Dip Switch 21 H Connection to a PC 22 I CN3 U...

Page 10: ...ring an innovative design offers the highest performance in terms of recognising legal coins and detecting false ones The special design of the drop duct has allowed for a significant reduction of the...

Page 11: ...upture of the packaging wet or damp patches or signs which indicate that the package has been exposed to rain frost or heat signs of tampering Also make sure that the content of the packaging correspo...

Page 12: ...HD coin validators required a multiple unit 20 packaging Fig 2 or a single unit packaging Both packaging consist of corrugated cardboard The packaging materials contained in it are made to meet the s...

Page 13: ...information For an easy identification of the coin validator i e its configuration operation mode and calibration type of accepted coins please find below a graphic representation of the labels affixe...

Page 14: ...with a maximum diameter of 31 5 mm and a maximum thickness of 3 4 mm Each of these two versions is available in four different models in order to meet any installation requirement Model Coin inlet Co...

Page 15: ...ersion B Version G B Front panel RM5 HD is compatible with F1 and F6 front panels and can be mounted either on the front or the rear of any machine For details regarding installation follow the instru...

Page 16: ...RM5 HD Operating Manual 16 Fig 6 B 2 Front panel F6 Fig 7...

Page 17: ...ble in 3 versions ccTalk Giochi Italia and Full Validator and totalizer Follow carefully the instructions below to ensure a correct connection for these three versions A Connection of the cc Talk vers...

Page 18: ...sm to the machine CPU by means of the CN2 ccTalk connector and to the separator by means of CN1 SEP connector as shown below Fig 10 Below is the pin numbering for the interested connector Pin number M...

Page 19: ...ing 1 Gnd 6 Inhibition 2 Vcc 7 CH1 3 CH 5 8 CH 2 4 CH 6 9 CH 3 5 CH 7 10 CH 4 D Connection of the parallel validator version with separator In presence of a separator connect the RM5 HD coin mechanism...

Page 20: ...sm to the machine CPU by means of the CN1 SEP connector as shown below Fig 13 Below is the pin numbering for the interested connector Pin number Meaning Pin number Meaning 1 Gnd 6 Inhibition 2 Vcc 7 3...

Page 21: ...the coin counter and the credit can be redirected to any pin chosen by the user from 7 to 10 Standard factory settings are those set as Default G Connection of the Virtual Dip Switch Each RM5 HD elec...

Page 22: ...or Pin number Meaning Pin number Meaning 1 Gnd 4 RX 2 5 Vdc 5 N U 3 TX 6 N U H Connection to a PC RM5 HD can be connected to a PC by means of a CN2 ccTalk connector This connection allows configuring...

Page 23: ...nts Configuration allows for example carrying out operations such as self learning modifying dip switches or some operating parameters RM5 HD can be configured by means of the mobile Virtual Dip Switc...

Page 24: ...ng activating recognition of coins with hole c Teaching RM5 HD to recognise a false coin d Inhibiting activating the anti fraud devices with which RM5 HD is provided Starting up the Self test function...

Page 25: ...ally designed for the GAMING industry It consists in a high number of specific controls aiming at a considerable control flexibility of a control unit called Host Machine specifications It is designed...

Page 26: ...w The table below shows two different sets of controls for the ccTalk Giochi Italia and ccTalk other configurations Full versions Header Custom Control Gaming ITALIA Other Config 1 Reset device X X 2...

Page 27: ...X 238 Test output lines X X 240 Test solenoids X X 241 Request software revision X X 242 Request serial number X X 243 Request database version X X 244 Request product code X X 245 Request equipment...

Page 28: ...sensor failed cash reject 0x06 0xXX Diameter sensors error Data byte 1 is a bitmask reporting which diameter sensor failed By means of control 229 Read buffered credit or error codes the ccTalk versi...

Page 29: ...5 Vdc inhibition state Following the insertion of a coin the coin mechanism sends the warning signal to the machine which at this point can decide whether to accept the coin earthing PIN 6 validator i...

Page 30: ...to 15 different coin values i e up to 62 coins provided that they are redirected on the first 15 channels Channel 1 is used to indicate the type of communication to the machine If disabled open collec...

Page 31: ...or is installed is disconnected from the power supply We strongly recommend following these instructions carefully in order to always keep the validator in the best operating conditions and to prevent...

Page 32: ...ntained in the Spare parts manual 8 Diagnosis and technical assistance In this section are described the main anomalies that may occur using this product with the possible solutions to minimise or eli...

Page 33: ...00 Supply Voltage Vdc 12 24 10 Current consumption mA Stand by Max 70 In acceptance Max 400 Temperature range C 25 70 Not condensed humidity 10 75 Accepted coins dimension 16 25 Minimum mm 17 27 Maxim...

Page 34: ...an automatic cash or vending machine In summary This equipment is not to be disposed of as unsorted municipal waste but must be disposed of separately Dealers will pick up used equipment free of charg...

Page 35: ...for every machine released onto the market 4 Manufacturers who in EEE use instructions do not provide the information as in article 13 paragraph 1 will be fined between 200 and 5 000 Euros 5 Manufact...

Page 36: ...g the exceptions as in article 5 paragraph 2 anyone releasing EEE containing substances listed in article 5 paragraph 1 after the 1st of July 2006 will be fined between 50 and 500 Euros for each unit...

Page 37: ...37 EN...

Page 38: ...RM5 HD Operating Manual 38...

Page 39: ...39 EN...

Page 40: ...Comestero Group S r l Via Marie Curie 8 20060 Gessate MI Tel 39 02 95781111 Fax 39 02 95 380178 www comesterogroup com comestero comesterogroup it...

Reviews: