Programming
For correct programming, follow the instructions below in order
I.
Configure button type
II.
Address button modules
III.
Program call addresses
code
DIP ON
1
1
12
3.4
23
1,2,3,5
2
2
13
1,3,4
24
4.5
3
1.2
14
2,3,4
25
1,4,5
4
3
15
1,2,3,4
26
2,4,5
5
1.3
16
5
27
1,2,4,5
6
2.3
17
1.5
28
3,4,5
7
1,2,3
18
2.5
29
1,3,4,5
8
4
19
1,2,5
30
2,3,4,5
9
1.4
20
3.5
31
1,2,3,4,5
10
2.4
21
1,3,5
11
1,2,4
22
2,3,5
TAB. A
Configure button type (single/dual)
DIP 6:
configuring button type:
Single button (
DIP6 ON
).
Dual button (
DIP6 OFF, default
).
I
Address button modules
DIP 1-5:
addressing call button module
(see TAB. A)
Addressing call button modules means that, in the event they are replaced, it is not necessary to reprogram the
button addresses. All you need to do is assign the same address as before to the new module.
II
Program call addresses
There are 2 programming methods:
•
Smart programming of consecutive addresses:
allows quick programming of buttons with consecutive addresses
(e.g.: 1, 2, 3, 4)
•
Programming of specific addresses:
allows programming of specific addresses (e.g.: 25, 37, 70, 58)
III
DIP 6:
configuring button type:
Single button (
DIP6 ON
).
Dual button (
DIP6 OFF, default
).