EN
22
4.2.3.2 HOW TO PROGRAM THE
INTERCOM FUNCTION
Example: key = general intercom to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f
Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
ON
1 2 3 4 6 7
5
8
2
2.1. Choose the function:
refer to the
and select a
S2
DIP switches
combination in which the intercom function (
INT
) is listed for the keys you wish to program.
Example: 0100
ON
1 2 3 4 6 7
5
8
2.2. Addressing:
f
for internal intercom
set S1 DIP switches with the same user code of the internal unit.
f
for general intercom to another user code
set S1 DIP switches with the desired address
ON
1 2 3 4 6 7
5
8
3
Select the key to be associated with the function
f
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
ON
1 2 3 4 6 7
5
8
5
When programming is complete,
f
Set
S2
DIP switches 1-2-3-4 to the combination 1111 (
PROG
setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000 (
"4.2.1 Preset function table")
.
f
Restore the user code setting on S1.
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8
4.2.3.3 HOW TO PROGRAM THE
PAGING FUNCTION
Example: key = general paging to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f
Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
ON
1 2 3 4 6 7
5
8
2
2.1. Choose the function:
S2
DIP switches
combination in which the paging function (
PAG
) is listed for the keys you wish to program.
Example: 0100
ON
1 2 3 4 6 7
5
8
2.2. Addressing:
f
for internal paging
set S1 DIP switches with the same user code of the internal unit.
f
for general paging to another user code
set S1 DIP switches with the desired address in
ON
1 2 3 4 6 7
5
8
3
Select the key to be associated with the function
f
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
ON
1 2 3 4 6 7
5
8
5
When programming is complete,
f
Set
S2
DIP switches 1-2-3-4 to the combination 1111 (
PROG
setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000 (
"4.2.1 Preset function table")
.
f
Restore the user code setting on S1.
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8