27
EN
4.3 RESET PROGRAMMING ART. EX-7000H
Factory settings:
• Button functions for the S2 DIP switch 1-2-3-4 combination;
• Intercom address absent;
• Range function and min./max. addresses absent;
• Ringtone reset.
Take note of the S2, S1 setting and restore it when programming is complete
1
2
3
DIP OFF
DIP ON
S1
S2 DIP
1 2 3 4 5 6
1 1 1 1 1 1
S2
5 sec
4.4 RANGE PROGRAMMING ART. EX-7000H
Take note of the S2, S1 setting and restore it when programming is complete
Carry out steps 1 to 4
1
2
3
4
Range minimum
address
S1
set code,
“TAB. A User
code” on page 30.
S2 DIP
1 2 3 4 5 6
0 0 0 0 1 0
S2
S2
Range maximum
address
Enable range
Disable range
Deleting the
range
DIP OFF
DIP ON
S1
S2 DIP
1 2 3 4 5 6
1 1 1 1 1 0
S2
2 sec