24
EN
4.2.3 Special key programming
If the preset function (see page
) do not reflect requirements, EACH KEY can be programmed differently
by carrying out the steps below.
Special key programming allow to programm the following functions:
•
generic actuator and coded actuator (ACT),
•
internal intercom calls and general intercom calls to another user code (INT),
•
internal paging calls and general paging to another user code (PAG),
•
Self ignition main external unit (AI),
•
Doctor function (D)
4.2.3.1 HOW TO PROGRAM THE ACTUATOR FUNCTION
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set S2 DIP switch 5-6 to the combination 01
» the privacy LED flashes
2
1. Choose the function:
refer to the the following table and select a
S2
DIP switches combination
in which the actuator function (
ACT
) is listed for the keys you wish to program.
DIP
S2
KEY PROGRAMMING
DIP 1
DIP 2
DIP 3
DIP 4
P1
P2
0
0
0
0
ACT
1
1
0
0
ACT
0
0
1
0
ACT
ACT
ACT
1
0
1
0
ACT
1
1
1
1
PROG
2. Addressing:
for generc actuator
set S1 DIP switches to the combination 11111111
for coded actuator
set S1 DIP switches with the desired address in accordance with
"TAB. A User code" on page 30.
Example
For P2=
generc actuator
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the privacy LED switches off
5
When programming is complete,
S
et
S2
DIP switches 1-2-3-4 to the combination 1111 (
PROG
setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (see the table above).
Restore the user code setting on S1, see
”TAB. A User code” on page 30.
4.2.3.2 HOW TO PROGRAM THE INTERCOM FUNCTION
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set S2 DIP switch 5-6 to the combination 01
» the privacy LED flashes
2
1. Choose the function:
refer to the the following table and select a
S2
DIP switches combination
in which the intercom function (
INT
) is listed for the keys you wish to program.
DIP
S2
KEY PROGRAMMING
DIP 1 DIP 2 DIP 3 DIP 4
P1
P2
0
1
0
0
INT
1
0
1
0
INT
1
0
1
1
INT
INT
1
1
1
1
PROG
2. Addressing:
for internal intercom
set S1 DIP switches with the same user code of the internal unit.
for general intercom to another user code
set S1 DIP switches with the desired address
in accordance with
“TAB. A User code” on page 30.
Example
For P1=
general intercom to
user code 3