Art. 6721W - Art. 6721W/BM
Page 1: ...EN Passion Technology Design TECHNICAL MANUAL Simplebus2 Mini hands free door entry monitor Art 6721W Art 6721W BM...
Page 2: ...tivities connected to the installation of Comelit products must be carried out by qualified technical personnel with careful observation of the indications provided in the Manuals Instruction sheets s...
Page 3: ...management as standard Option of adding 3 additional buttons with accessory art 6734W Complete with 2 dip switches with 8 positions for user code programming and button programming The monitor can onl...
Page 4: ...olding keys on page 4 AUTOMATIC ANSWER Hands Free function See paragraph Pressing and holding keys on page 4 INTERCOM Call from one internal unit to one or more internal units CALL TO A MAIN OR SECOND...
Page 5: ...rption W 0 05 0 05 Maximum absorption W 8 8 8 8 HARDWARE CHARACTERISTICS Type of buttons Capacitive Capacitive No of programmable buttons for additional functions 2 5 with accessory art 6734W 2 5 with...
Page 6: ...6 Installation 1C 1B 1A 4 3 2 6 2 1 5 fissaggio opzionale 115 mm 160 mm 1 2 FACILITATED OPENING...
Page 7: ...ng simultaneously Main and secondary door entry monitors Settings In systems with power supply unit 1209 1210 or 1210A it is possible to set a maximum of 1 main door entry monitor In systems with powe...
Page 8: ...A OFF OFF OFF OFF AP ACT AI CCS D PAN B ON OFF OFF OFF AP CCS AI INT INTb D C OFF ON OFF OFF AP INT AI INTb ACT CCS D ON ON OFF OFF AP ACT CCS CCP PAN K E OFF OFF ON OFF ACT ACT ACT ACT ACT ACT F ON...
Page 9: ...configuration table 4 Set the S1 DIP switches according to the call address of the desired apartment See Addressing table on page 13 5 Press and release the button to be associated with the function C...
Page 10: ...selective intercom address to a maximum of 3 devices TABLE B Code S1 DIP switch ON Code S1 DIP switch ON Code S1 DIP switch ON 1 1 4 4 7 7 2 2 5 5 8 8 3 3 6 6 Generic actuator coded actuator Generic...
Page 11: ...he function Correct procedure indication the LED flashes for a few seconds and a confirmation tone sounds 6 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP swi...
Page 12: ...mation tones are emitted to change the floor door call ringtone Any further pressing of the button repeats the sequence described above 3 Press and release to scroll through the available ringtones in...
Page 13: ...96 3 7 8 226 2 6 7 8 17 1 5 47 1 2 3 4 6 77 1 3 4 7 107 1 2 4 6 7 137 1 4 8 167 1 2 3 6 8 197 1 3 7 8 227 1 2 6 7 8 18 2 5 48 5 6 78 2 3 4 7 108 3 4 6 7 138 2 4 8 168 4 6 8 198 2 3 7 8 228 3 6 7 8 19...