TECHNICAL AND OPERATION MANUAL 41LTS000
Passion.Technology.Design.
Modify
Down
Right
Enter
Esc
Up
Loop Tester
Loop A
Loop B
Page 1: ...EN TECHNICAL MANUAL TECHNICAL AND OPERATION MANUAL 41LTS000 Passion Technology Design Modify Down Right Enter Esc Up Loop Tester Loop A Loop B...
Page 2: ...r Cable Faults 7 4 5 Perform Loop Tests 8 4 5 1 Loop State 8 4 5 2 Loop Tools 9 4 5 3 Bisection Method for Faults Searching 9 4 5 4 Reading Device Parameters 9 4 5 5 Searching Short Break Faults 10 4...
Page 3: ...evices in the Appendix In case of installed devices without isolators in present operating fire alarm systems you have to consider that they will be displayed as separate branches in the system When y...
Page 4: ...the cursor on left right Esc Reject the set parameters Exit one step back from a sub or main menu Cancelation of test or addressing procedure 3 Connection Diagrams 3 1 Loop Connection Attention The lo...
Page 5: ...ly switch to the new set language 4 3 Reading a Topology of a Loop Line The Loop Tester operation test and addressing procedures always starts from Loop Side A to Loop Side B see item 3 1 A list with...
Page 6: ...nstalled cable which can disturb the operability of the loop line Attention The tests must be performed with no connected devices to the cable If there are connected devices they have to be disabled o...
Page 7: ...on To escape from the Cable Tests menus press ESC button several times 4 4 3 Searching for Cable Faults If an error message is displayed in Auto Cable Test menu you can run the separate single test ag...
Page 8: ...Cable tests Loop Tests Addressing Language Loop State Loop Tools Select Loop State menu and press ENTER The message Please wait and a process bar are shown during analysing the current loop state The...
Page 9: ...rameters Short Break Fire position Branch position In the Loop Tools menu are included the following operations for precise finding of troubles and devices in the loop configuration You can scroll wit...
Page 10: ...position Addressed loop Unaddressed loop According the organization of the system configuration there are two approaches to start test Addressed loop Use this option when the devices in the loop are w...
Page 11: ...ire MCP150 008 MCP150 055 To escape from the Fire position menu single press ESC button 4 5 7 Searching for Branch Position The branch is a sub loop to the main loop The connection topology diagrams a...
Page 12: ...e LEDs of the device are switched on Turn ON OFF Enter address 001 Turn ON Turn ON OFF Enter address 001 Turn OFF To switch off the LED indication press the ENTER button again the field is changed to...
Page 13: ...Autoaddressing IS menu and press ENTER button To start the procedure select Yes option and press ENTER again During the addressing procedure the screen displays the current number of found addressed...
Page 14: ...Current addr 001 Set new addr Change address Current addr 001 Set new addr 009 After successful changing a message Successful will appear on the last row of the screen If Busy new address message is...
Page 15: ...ected during installation 41IOM000 Module with 1 output Yes must be connected during installation 41IOM000 240 Module 240V interface with 1 output Yes must be connected during installation 41IOM010 Mi...
Page 16: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...