Comdel Warranty  

 

Seller fully warrants that equipment, service, software, repair or parts supplied shall conform to the description in 

the quotation and agrees to repair or replace F.O.B. shipping point, any parts (excepting expendable items such as 
semiconductors and vacuum devices), services, or repairs that fail due to defects in material or workmanship within 

(1) one year of start-up of equipment or (24) twenty four months after shipment, whichever occurs first, or in the 

case of service or repair, within (1) one year of rendering service or repair.  At Buyers request, failure analysis will 

be provided for all in-warranty failures returned by Buyer to Comdel Gloucester.  Liability of Seller under this 
warranty shall exist provided that: Buyer exposes the product to normal use and service; in case of shipping 

damage, Buyer notifies Seller within 30 days of receipt of goods; the Buyer receives a Return Materials 

Authorization (RMA) number from Seller prior to the return of product for repair; if upon examination of such 

product by Seller it is disclosed that a defect in materials and/or workmanship does exist, and the defect in the 
product was not caused by improper conditions, misuse, abuse or negligence; and that Sellers warranty decals 

have not been removed or tampered with and the equipment has not been repaired or modified by anyone other 

than Seller’s authorized personnel. Other than those expressly stated herein, there are no other warranties of 

any kind, expressed or implied, and specifically excluded, but not by way of limitation, are the implied 
warranties of fitness for particular purpose and merchantability.
 

 

It is understood and agreed that Seller’s liability, whether in contract, in tort, under any warranty, in 

negligence or otherwise shall not exceed and Buyer’s remedy is limited to either (i) repair or replacement of 
the defective parts F.O.B. shipping points, correction of the defective service or repair, or at Seller’s option 

(ii) return of the product and refund of the purchase or service price.  Under no circumstances shall Seller 

be liable for special, indirect, incidental, or consequential damages.  The price stated for the equipment, 

service, repair or parts is a consideration in limiting Seller’s liability.  No action, regardless of form, arising 
out of the transactions of this agreement may be brought by Purchaser more than one year after the cause 

of action has accrued.  The warranty for the equipment, service, repair or parts proposed in this quotation is 

as stated in the above paragraphs.  It is not re-stated nor does it appear in any other form. 

 

 

Summary of Contents for CDX2000

Page 1: ...n this manual is proprietary to Comdel Inc and is protected by copyright and trademark laws You may not modify copy reproduce republish post transmit or distribute in any way any material from this manual except as may be expressly permitted in writing by Comdel Inc Comdel Inc 11 Kondelin Road Gloucester MA 01930 Phone 978 282 0620 www comdel com COMDEL ...

Page 2: ...l Operation 10 B Remote Control Operation 11 7 Theory of Operation 12 A AC Interlock System 12 B DC Power Supply 12 C Oscillator Control Board 13 D Driver 14 E PA 1250S Power Amplifier 14 F LF1250 Power Amplifier 14 G Directional Coupler Board 14 H CDX Controller 15 I CDX Autotune Parameters 15 8 Certification 16 9 Customer Service 17 List of Figures FP5315RX CDX2000 Block Diagram FA0900RX AC Inte...

Page 3: ...l indicates the presence of high voltages in or around the unit This symbol indicates that the component or circuit is short circuit protected This symbol indicates the presence of RF energy in or around the unit This symbol indicates a protective earth ground connecting point This label indicates a presence of high voltage in or around the equipment which may cause sever injury or death All appro...

Page 4: ...And Understand This Section Fully Before Installing or Operating This Equipment WARNING This equipment must be installed operated and serviced only by trained qualified persons General Safety Requirements WARNING Hazardous Voltages and RF voltages are present inside this unit which may cause injury or death To prevent electrical shock and or RF burns never operate this equipment with the covers re...

Page 5: ...nimum interlock protection is located at the removable top cover bottom cover and RF output connector safety cover End user s system should provide indication to the operator of the interlock fault condition Low voltage power for the interlock circuit is supplied by a step down transformer located inside the unit This transformer is designed to provide safe low voltage operation and provide isolat...

Page 6: ...a 1 25 VSWR load all phases as reference to 50 ohms The unit shall be capable of simultaneously supplying 1000 W of power at 400 kHz into a 50 ohm power load and 1000 W of power at 13 56 MHz into a separate 50 ohm power load The 13 56 MHz output shall deliver 0 to 1000 W continuous forward power into a load which consists of a 50 ohm coaxial cable any electrical length feeding a matching network t...

Page 7: ...ure to self adjust frequency for the lowest VSWR over this range The auto tune feature should operate independent of the length of coaxial cable used to interface the output to the plasma resonant load The auto tuning frequency sweep will be of a continuous nature or comprised of discreet frequency steps of step size no larger than 100 Hz This should be capable of auto tuning to within 0 8 kHz of ...

Page 8: ...nections Description Specifications Signal Input Impedance 10K ohms minimum Signal Input Isolation 1000 VAC MIN to the A C supply line Rear Panel Electrical Connections All electrical connections shall be placed at least 75mm 3 from the right and 100mm 4 from the left side of the rear panel when viewed from the rear for clearance purposes Input Power Connection Line cord to be 4 mm2 12 AWG conduct...

Page 9: ...tached flush with bottom of power supply chassis Color and Finish Front panel to be the only surface to be painted gray with contrasting blue alpha numeric reference designators All other surfaces have a coated finish such as gold zinc chromate gold alodyne or equivalent Water Connections 1 4 NPT female one inlet and one outlet for water cooling of amplifier sections The water connections shall be...

Page 10: ...mum levels permitted by ANSI C95 1 1982 standards on safety levels with respect to human exposure to RF and electromagnetic fields from 300KHz to 100GHz F Testing Specifications Production Acceptance Test Each unit will be required to pass production acceptance testing and a Final Test Report will be generated to document results Production Acceptance Testing process shall include as a minimum Com...

Page 11: ...stance 4 Maintenance The CDX2000 is designed to operate unattended for long periods of time Should periodic maintenance or service be required it should only be performed by qualified service persons Contact the factory for maintenance or service recommendations 5 Preparation for Use A Line Requirements The CDX2000 is designed to operate from a 208 VAC three phase line The system will still functi...

Page 12: ... 9 must be connected for the unit to be operated These jumps must be made on both I O connectors 1 Check to see that there is clearance around the unit for proper air flow and that a proper RF load is connected to each RF output connector at rear of unit 2 Connect unit to 208VAC nominal three phase and turn on main power breaker at rear of unit 3 The CDX2000 should power up automatically autostart...

Page 13: ... on the front panel 11 An overtemp condition due to improper clearance around the unit or high ambient temperature will automatically disable both RF outputs on the CDX2000 The front panel display will show OVERTEMP RF will not be able to be turned on until proper coolant flow temperature is established B Remote Control Operation 1 4 Refer to Control pinout and signal table for the electrical inte...

Page 14: ...Figure FP5315RX CDX2000 BLOCK DIAGRAM to see how the individual modules are connected together The LF1250 amplifier s frequency can be manually adjusted between 380 420 kHz from the front panel local mode only or the amplifier can Autotune to minimize reflected power The Autotune algorithm is carried out in the generator s firmware and is optimized to tune quickly in a plasma load There are some a...

Page 15: ...erence level applied to the non inverting input The reference level is set either from the front panel potentiometer or from Pin 5 of the J1 connector The LM 356 drives the gain control transistor Q5 until enough signal from the forward power detector in the directional coupler is applied to the inverting input to the op amp When the inverting signal equals the reference voltage on the non inverti...

Page 16: ... of these transformers is once again added together in a four way hybrid combiner There are no adjustments on the PA1250S Typical Specifications PA1250S Gain 15 dB Input power 20 watts Output power 1500 watts min Input impedance 50 ohms Output impedance 50 ohms Collector voltage 37 VDC Current draw 50 ADC At 1250 watt system output into 50 ohm resistive load F LF1250 Power Amplifier The LF1250 pow...

Page 17: ...r any reason the program is terminated or gets lost the watchdog timer U6 automatically restarts the system U6 also monitors VCC for low voltage conditions If VCC drops below 4 5V the system is shut down via uP reset line U1 71 If the optional RS 232 serial port is utilized U7 and associated components supplies the interface U14 provides the 5V or 10V reference for the A D U11 and D A U13 converte...

Page 18: ...and varies as follows 0 5 1 1 2 2 3 3 4 Scale The scale setting determines whether the frequency step size is proportional to the SWR or the square root of the SWR The scale is set by switch 7 Typically the square root setting will tune faster 0 SQUARE ROOT 1 LINEAR 5 Start The start setting determines whether the frequency starts at MIN frequency and tunes up or starts at MAX frequency and tunes ...

Page 19: ...on warranty products When sending equipment to the factory for service or calibration you need a Return Material Authorization RMA number to ensure that we can properly track your equipment Obtaining an RMA Number To complete an online request for an RMA number log on to www comdel com and click on Factory Service under the Sales Service Menu or for direct access go to http www comdel com pages sa...

Page 20: ...ffer application support RF training and product design assistance All are fully supported by the product marketing and engineering team at Comdel s headquarters International Offices EUROPE Comdel United Kingdom ARD Phone 44 1256 766914 or 44 1256 766917 Fax 44 1256 766915 Email steve_ottaway comdel com MIDDLE EAST Israel Odem Scientific Applications Ltd Phone 972 8 9366101 Fax 972 8 9366102 Emai...

Page 21: ...mproper conditions misuse abuse or negligence and that Sellers warranty decals have not been removed or tampered with and the equipment has not been repaired or modified by anyone other than Seller s authorized personnel Other than those expressly stated herein there are no other warranties of any kind expressed or implied and specifically excluded but not by way of limitation are the implied warr...

Page 22: ...CDX2000 13 56 MHz 400 kHz Manual 2006 Comdel Inc 20 ...

Page 23: ...CDX2000 13 56 MHz 400 kHz Manual 2006 Comdel Inc ...

Reviews: