7
TECHNICAL SPECIFICATION
(tested under the conditions of ambient temperature 15°C and tap water temperature 10°C)
Model
Ice Making Capacity – 24
hours
Climate Electrical
Class
Power Input
(W)
Dimension
L×D×H(mm)
VDB-26
26Kgs
N
I
220
420×528×655
VDB-50
50Kgs
N
I
280
496×610×792
The specifications are subject to be changed without notice. Please check the nameplate for sure.
TROUBLE AND SHOOTING
(for reference of users and technicians)
Disconnect Ice Maker from power before carrying out any of these checks.
TROUBLE
CAUSE
REMEDY
The ice marker does
not work
1.The voltage is out of the
limitation.
2.The ambient temperature is
lower than 10º C.
1.Stop the ice maker and restart it until the
voltage is normal.
2.Try again when the ambient temperature
higher than 10ºC
Water shortage
indicator lights on.
1.Water shortage from the water
supply system.
2. Water valve damaged.
3.Tap water pressure too low.
1.Check the water supply.
If it is OK, restart the maker.
2.Check the water valve.
3.Be sure the tap water pressure is higher
than 1 kg/cm
2
Compressor doesn’t
work
1.Water shortage.
2.Ice full.
1.
Check the water supply system (water
valve and water supply tube).
2. Take out some ice.
Compressor works,
but no ice is made.
1.Refrigerant leakage.
2.The refrigerating system is
blocked.
1.Recharge the refrigerant and check the
leakage again.
2.Charging N2to check whether
The system is blocked and replace the
dryer-filter
3.Replace the solenoid valve
4.Check whether the fan is running.
It is difficult for ice
dropping or ice
cannot be dropped.
1.
Water temperature or
ambient temperature is too
low.
2.
The solenoid valve is
damaged.
1. Check whether the ambient
temperature is too low (Lower than 10 ºC)
or water temperature is too low(lower
than 7 ºC)
2. Replace the solenoid valve.
Trouble indicator
lights on.
The water box does not tilt.
Unplug the power, check the tiling motor
and relative system. 3~5 minutes later
restart the machine.