33
32
EN
EN
4.4 Electrical connection
The electrical connection must
be carried out by a qualified
electrician, in compliance with
the regulations in force.
Make sure the equipment is connected to
an efficient earthing system and that the
line voltage matches that specified on the
machine’s rating plate.
Connect the power cable to
an easily accessed 30 mA
differential thermal-magnetic
wall switch with contact gap
of at least 3 mm.
Make sure the power cable has not been
damaged or crushed during handling.
If necessary, it must be replaced
only by an authorised installer.
Do not plug the power cable in
before completing installation
and fitting the cover panels.
The machine must be connected
to an equipotential system,
connecting the cable in the rear
terminal next to the symbol.
4.5 Safety devices installed
The machine has some devices that allow
safe use.
- The internal wiring has a thermo-
amperometric contactor which stops the
wash in case of a pump fault.
- A magnetic micro switch stops the wash in
case of accidental opening of the door.
- Manual reset thermostats switch off the
heating elements in case of overheating of
water.
- An overflow pipe keeps the tank water
level constant.
- A safety pressure switch prevents the
water inside the machine from exceeding
the maximum level.
The manufacturer declines any
liability for damage or injury
resulting from tampering with
or the non-use of these devices
or due to non-compliance with
the above instructions and the
electrical safety regulations
in force in the country of
installation.
5. DESCRIPTION OF CONTROLS
The control interface is different for the various models.
5.1 Electromechanical version
1. Water temperatures.
2. Activate drain pump button (option).
3. Start cycle button.
4. Wash cycle ON indicator.
5. Cycle time selector (minutes).
6. Machine temperature ready-to-wash indicator.
7. ON-OFF button.
8. Power ON indicator.
5.2 Electronic version with LCD display
1. ON-OFF button (press 2 seconds for ON)
2. Programming menu access button (press 3 seconds).
3. Drain pump/Self-cleaning button and ESC function when programming.
4. LCD display.
5. Select cycles and up/increase (+) function button used in programming.
6. Enable cold rinse (option) and down/decrease (-) function button when programming.
7. Start cycle luminous button and Enter function when programming.
When the machine is OFF, the message “OFF” appears on the display and the tension indicator
8 is red.
CONNECT USING CABLE OF
MIN. SECTION 10 mm²
V : 5 5 ° C B : 8 2 ° C
60”
Summary of Contents for 7280.0070
Page 72: ...143 142 RU RU 70 dB A 3 1 2 3 4 5 6 7 8 3 1 P K 4 3 40 4 1 5 C 40 C PRS 1 2 3 6 7 8 5 4...
Page 73: ...145 144 RU RU 4 2 10 4 3 100 500 1 5 200 500 2 5 20 f 4 3 4 10 C 50 C ES 25 800 4 4 30 3 10 10...
Page 74: ...147 146 RU RU 4 5 5 5 1 1 2 3 4 5 6 7 8 5 2 1 2 2 3 3 4 5 6 7 OFF 8 V 5 5 C B 8 2 C 60...
Page 75: ...149 148 RU RU 6 6 1 4 3 6 2 3 0 0 12 0 0 82 0 82 0 12...