6 Technical data
Power supply
Voltage supply
8-36V DC
Consumption depends on supply
voltage
0,7A at 8
VDC
Operating conditions
Operating temperature
-20...+70oC
Storage temperature
-30...+80oC
Flash memory data retention time
10 years
IP Protection
IP65
Standard conformity
Low Voltage Directive
EN 61010-1:95
+A1:97
Electromagnetic
Compatibility
EN 61000-6-3
EN 61000-6-4
EN 61000-6-1
EN 61000-6-2
Vibration
EN 60068-2-6
Mechanical
Front panel
245x164mm
LCD display cut-out
175x115mm
Weight
855g
CAN bus interface
Maximal CAN bus lenght:
CAN bus mode = 250 kBd
200 m
Maximal CAN bus lenght:
CAN bus mode = 50 kBd
900 m
Nominal impedance
120
W
Cable type
twisted pair (shielded)
Nominal Velocity of
Propagation
min. 75% (max. 4,4
ns/m)
Wire crosscut
min. 0,25 mm2
Maximal attenuation (at 1
MHz)
2 dB / 100m
Recommended Industrial Automation & Process
Control Cables:
BELDEN (
):
3082A DeviceBus for Allen-Bradley DeviceNet
3083A DeviceBus for Allen-Bradley DeviceNet
3086A DeviceBus for Honeywell SDS
3087A DeviceBus for Honeywell SDS
3084A DeviceBus for Allen-Bradley DeviceNet
3085A DeviceBus for Allen-Bradley DeviceNet
3105A Paired EIA Industrial RS485 cable
LAPP CABLE:
Unitronic BUS DeviceNet Trunk Cable
Unitronic BUS DeviceNet Drop Cable
Unitronic BUS CAN
Unitronic-FD BUS P CAN UL/CSA
HW modifications IV 5 CAN
CAN Galvanically Isolated
Yes
Binary Output
Yes
Analog Input
Yes
Backlight Keys
No
Protected IP
IP-65
HW modifications IV 5 CAN Backlit
CAN Galvanically Isolated
Yes
Binary Output
Yes
Analog Input
Yes
Backlight Keys
Yes
Protected IP
IP-65
LCD specifications
LCD panel
5,7"
Resolution
320 × 240 pixels
Pixel Pitch
0.120 x 0.360 mm
InteliVision 5 CAN - 1.3.0, Global Guide
50