Signalization LEDs
There are 5 LEDs for indication of InteliPro status with the meaning indicated in the table below:
LED
state
Meaning
(red)
-
Status of the InteliPro unit - used in combination with green LED, see the table below
(green)
-
Status of the InteliPro unit - used in combination with red LED, see the table below
(green)
ON
CB1 feedback - activated - state "I"
OFF
CB1 feedback - deactivated - state "0"
(green)
ON
CB2 feedback - activated - state "I"
OFF
CB2 feedback - deactivated - state "0"
(red)
ON
Indicates TRIP state, measured values are in fault conditions (out of limits)
(red)
blinking
Indicates TRIP state, measured values are in fault-free conditions (within limits). It is
possible to terminate the TRIP state by any of the mthods of of Fault Reset.
OFF
The unit is not in TRIP state
Status LED signalization:
red
green state
Display reading
Meaning
OFF OFF
No power supply or PowerFail occured
blink OFF
"Program Corrupted" or
"System Error" or "System
Error + Wrong config
format"
Transient SW failure → Contact technical support with
information abut the display message
ON
OFF
Normal reading
Wrong checksum of parameters → Check the complete settings
of your unit and change any one of the parameters. If the state
persists, contact technical support
ON
ON
Normal reading
Wrong checksum of "R" parameters → Contact
technical support
blink ON
Normal reading
Watchdog reset was performed → Save the archive, contact
technical support and
attach the archive
OFF ON
Normal reading
Normal operation of the unit
blink blink
Not initialized
Unit HW failure → Request repair of the unit