background image

ComAp,a.s.

 

Kundratka 2359/17 
180 00, Praha 8 
Czech Republic 

InteliNano-NT MRS, SW version 1.5, 

©ComAp – September 2013                                               1 

InteliNano-NT-MRS-1.5-Fast User Guide.pdf 

CAN INTERFACE

GENERATOR VOLTAGE 

MEASUREMENT

T16 = Neutral
T17 = Phase 1
T18 = Phase 2
T19 = Phase 3

USB interface

L

COM

H

INTPUT TERMINALS

T10 = COM for analog inputs
T11 = binary input
T12 = binary input
T13 = binary/analog input – Low Fuel Level
T14 = binary/analog input – Coolan Temperature
T15 = binary/analog input – Oil Pressure

OUTPUT TERMINALS

T04 = binary output – Starter (6A)
T05 = binary output - Fuel Solenoid (6A)
T06 = binary output (500 mA)
T07 = binary input/output (500 mA)

POWER SUPPLY, D+

T01 = BATT -
T02 = D+
T03 = BATT +

 

G

ECU

DIESEL / GASOLINE ENGINE

GENERATOR

LOAD

Fu

e

l S

o

le

n

o

id

B

at

te

ry

Sa

rt

e

r

Fu

e

l L

e

ve

l A

n

alo

g

C

o

o

la

n

t T

e

m

p

e

ra

tu

re

 A

n

alo

g

O

il P

re

ss

u

re

 A

n

alo

g

D+

-

+

A

la

rm

R

e

ad

y T

o

 L

o

ad

Fu

e

l S

o

le

n

o

id

St

ar

te

r

C

O

M

R

e

m

o

te

 S

ta

rt

 A

n

d

 L

o

ad

Em

e

rg

e

n

cy

 S

to

p

C

A

N

L C

O

M

 H

U

SB

B

at

te

ry

 +

B

at

te

ry

 -

D

 +

PC

L1

L2

L3

N

InteliNano NT

 

MRS

 

 

 

 

 Fast User Guide 

 

Typical wiring diagram 

 
 

 

 

 

 

 

 

 

 

 

Accessing the setup mode 

Ensure the engine is stopped and the controller is in Manual mode (green LED above button

 

Auto

 

is turned off).

 

If you have not configured the custom initialization (init) screen then press and hold 

Stop

 

button, then briefly press 

 

button

 

and then 

Auto

 .  

 

If you have already created your own init screen then press and hold 

Stop

 

button and then briefly press  

, the custom init screen will appear, keep holding the 

Stop

 

button. Then press

 

 

to switch LCD to default init screen, and then press

 

Auto

 

To move up and down in the setup menu use

 

 

and

 

 

buttons. Press

 

Start

 

button to select or

 

Stop

 

button for exit.

 

 

 

Basic settings

 

 

Input settings

 

 

Engine parameters and protections

 

 

ECU setting

 

 

Generator protections

 

 

Info

 

 

Output settings 

 

 

Outputs and inputs 

Output 
code 

Output source 

Type 

Terminal assignment 

O00 

Not Used

 

binary  T04, T05, T06, T07 

O01 

Starter

 

binary  T04 

O02 

Fuel Solenoid

 

binary  T04, T05, T06, T07 

O03 

Stop Solenoid

 

binary  T04, T05, T06, T07 

O04 

Alarm

 

binary  T04, T05, T06, T07 

O07 

Ready To Load

 

binary  T04, T05, T06, T07 

O08 

Prestart

 

binary  T04, T05, T06, T07 

O09 

ECU Power Relay

 

binary  T04, T05, T06, T07 

O10 

Choke 

binary  T04, T05, T06, T07 

O11 

Glow Plugs 

binary  T04, T05, T06, T07 

 

  Normally Open Contact – output 

 

Normally Open Contact - input 
button 

  Normally Closed Contact – output 

 

Normally Closed Contact 

– input 

button 

 

User curves

 

 

I21

 

I23

 

I25

 

  VDO Level % 

VDO 5 Bar 

VDO 40-

120 °C 

  Datcon Level % 

VDO 10 Bar 

VDO 50-

150 °C 

   

Datcon 5 Bar 

Datcon High °C 

   

Datcon 7 Bar 

Datcon Low °C 

   

Datcon 10 Bar 

 

  Not selected 

Not selected 

Not selected 

 

Input 
code 

Input source 

Type 

Terminal assignment 

I00 

Not Used

 

binary  T07, T11, T12, T13, T14, T15 

I01 

Emergency Stop

 

binary  T07, T11, T12, T13, T14, T15 

I02 

Remote Start/Stop

 

binary  T11 

I03 

Remote Start And Load

 

binary  T11 

I04 

Access Lock

 

binary  T07, T11, T12, T13, T14, T15 

I07 

GCB Feedback

 

binary  T07, T11, T12, T13, T14, T15 

I10 

External Warning 1

 

binary  T07, T11, T12, T13, T14, T15 

I11 

External Warning 2

 

binary  T07, T11, T12, T13, T14, T15 

I12 

External Warning 3

 

binary  T07, T11, T12, T13, T14, T15 

I13 

External Shutdown 1

 

binary  T07, T11, T12, T13,T14, T15 

I14 

External Shutdown 2

 

binary  T07, T11, T12, T13, T14, T15 

I15 

External Shutdown 3

 

binary  T07, T11, T12, T13, T14, T15 

I20 

Low Fuel Level

 

binary  T07, T11, T12, T13, T14, T15 

I21 

Fuel Level Analog

 

analog  T13, T14, T15 

I22 

Low Oil Pressure

 

binary  T07, T11, T12, T13, T14, T15 

I23 

Oil Pressure Analog

 

analog  T13, T14, T15 

I24 

High Coolant Temperature

 

binary  T07, T11, T12, T13, T14, T15 

I25 

Coolant Temperature Analog

 

analog  T13, T14, T15 

I29 

Fuel Level SD 

Binary  T07, T11, T12, T13, T14, T15 

 
 
 
 
 
 
 
 
 
 
 
 

Dimensions

 

Case dimensions:

 

118mm x108mm x 40mm 

Panel Cutout: 96mm x 96mm 

 

W

ARNING

!

 

 

If D+ is not used, connect this terminal to battery positive!  

 