Setpoint group
Engine parameters
Related FW
2.5.0
Range [units]
0 .. 3000 [RPM]
Default value
0
-
Step
1
Comm object
11125
Related applications
Description
Limit for Speed Request transformation from RPM to % range for ECU engines using % format.
Example:
If ECU is configured, then on one of the measurement screen you can see two lines SpeedReq Abs
and SpeedReq Rel.
In default setting:
0 RPM = 0 %
800 RPM = 33.3 %
2400 RPM = 100 %
Different setting:
800 RPM = 0 %
1200 RPM = 33.3 %
2400 RPM = 100 %
It is possible easily configure own output curve and use it for analog output Speed Request.
0%ofSpeedReq
Setpoint group
Engine parameters
Related FW
2.5.0
Range [units]
0 .. 4000 [RPM]
Default value
2000
-
Step
1
Comm object
11126
Related applications
Description
Limit for Speed Request transformation from RPM to % range for ECU engines using % format.
100%ofSpeedReq
Setpoint group
Engine parameters
Related FW
2.5.0
Range [units]
0 .. 600 [s]
Default value
7
-
Step
1
Comm object
11835
Related applications
Description
Horn time before the conveyor output starts.
Conveyor horn
Summary of Contents for InteliDrive FLX LITE
Page 19: ...ID FLX Lite Global Guide 19 4 3 Terminal diagram and dimension ...
Page 21: ...ID FLX Lite Global Guide 21 Example Default analog output curves ...
Page 22: ...ID FLX Lite Global Guide 22 Example Wiring for Dacon gauges and IL NT AOUT8 ...
Page 44: ...ID FLX Lite Global Guide 44 5 2 Binary inputs and outputs ...
Page 57: ...ID FLX Lite Global Guide 57 5 14 Display screens and pages structure ...
Page 83: ...ID FLX Lite Global Guide 83 7 Communication 6 back to Table of contents ...