Engine running state
RPM > Engine params:
Starting RPM
or
Logical Analog Input
Oil Press
> Engine params:
Starting Poil
or
Logical Analog Input
Coolant Press
> Engine params:
StartPCoolant
(
PRP
only) or
active BI
RunIndication1
or
active BI
RunIndication2
or
active BI
RunIndication3
.
3.1.3 Operational modes
LOC (Local) mode
LOC
(Local) mode can be set in any mode mentioned above –
AUX, EME, HRB, PRP
. ID-DCU MARINE
receives only commands entered from the ID-DCU MARINE front panel in LOC (Local) mode. All external
interfaces – binary inputs
Remote Start, Blackout Start, RemRepStart, Remote Stop, Rem Start/Stop
and
serial line commands are disabled.
LOC
(Local) mode is activated and deactivated using ID-DCU MARINE front panel buttons: Enter + Mode→ to
activate, Enter + ←Mode to deactivate. Active
LOC
(Local) mode is indicated in the upper right corner of the ID-
DCU MARINE display.
OFF mode
All ID-DCU MARINE controller and ID-RPU binary outputs are switched off. Engine can’t be started or running
engine is stopped, prelubrication function is not active. Firmware and controller configuration can be changed in
OFF
mode only.
OFF
mode is available in all applications –
AUX, EME, CMB
and
PRP
.
Auxiliary mode (AUX archive)
AUX
mode is designed for auxiliary engines.
Controller starts and stops the engine according to the binary inputs
Blackout Start
or
Remote Start
,
Rem
Start/Stop
,
Remote Stop
or to the ID-DCU MARINE
Start / Stop
buttons. Binary inputs Blackout Start
and Remote Start and Remote Stop are inactive in
LOC
(Local) mode.
All engine protections and all configured shutdown protections are active. Controller continuously monitors
all available engine parameters (oil pressure, water temperature, RPM, fuel level etc.). The engine will stop
and activates
Common Warning
and
Common Shutdown
outputs and writes record to the history file
when detects any active Shut down alarm. This condition can be signaled by Active call feature to remote
operator via modem, SMS or e-mail.
Emergency mode (EME archive)
The engine is used for emergency engines.
Controller starts and stops the engine according to the binary inputs
Blackout Start
or
Remote Start
,
Rem
Start/Stop
, Remote Stop or to the ID-DCU MARINE
Start / Stop
buttons. Binary inputs
Blackout Start
and
Remote Start
and
Remote Stop
are inactive in LOC (Local) mode.
The controller still measures all engine parameters. But it only records to the history file and can notify
remote operator via Active call when detects any parameter out of range.
The only active shut down protection is engine overspeed and Emergency stop.
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...