InteliDrive DCU Marine - 3.0.0 Global Guide
206
Related FW
3.0.0
Related applications
All
Comm object
40
Description
The output closes when engine starts and opens AfterCoolTime delayed after stop the engine.
Cooling Pump
Related FW
3.0.0
Related applications
All
Comm object
81
Description
Indicates correctly running firmware when cycling on/off with 0,5s period.
Watchdog
Related FW
3.0.0
Related applications
All
Comm object
755
Description
Output is closed when panel 0/1 (On/Off) button is pressed or Binary input Remote On/Off is closed and
engine RPM is over
Engine protection
: MinLoadSpeed.
Output opens when RPM is bellow MinLoadSpeed. Close load can´t be opened by button when Binary input
Remote On/Off (level sensitive) is closed.
Function can be blocked by binary input Load blocking.
Close Load
Related FW
3.0.0
Related applications
AUX, EME, CMB
Comm object
265
Description
The output is closed/opened with rising edge of Binary input Rem On/Off (or I/0 front panel button) when
engine is in Running state and engine RPM is over MinLoadSpeed. Output opens when RPM is below
Close Load (AUX, EME, CMB, only)
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...