InteliDrive DCU Marine - 3.0.0 Global Guide
201
Related FW
3.0.0
Related applications
All
Comm object
6
Description
The output closes when any Sensor fail alarm is active. Output opens when all Fls alarms disappear and
Fault reset is pressed (no Fls alarm in Alarm list).
Common Fls
Related FW
3.0.0
Related applications
All
Comm object
1942
Description
Provides feedback information that command (LBI function)
is active
CMD RegInhOn
Related FW
3.0.0
Related applications
All
Comm object
17
Description
TThe output is closed in controller OFF mode.
OFF Mode
Related FW
3.0.0
Related applications
All
Comm object
1831
Description
Active signal indicates that DPF (Diesel Particulate Filter) is starting to overfill with soot because the
system is unable to undertake an automatic active regeneration. It starts flashing when the DPF is nearly
full, engine power may be reduced.
DPF Lamp
Related FW
3.0.0
Related applications
PRP, AUX, HRB
Comm object
9887
Description
PRP Mode (PRP only)
The output is closed in controller PRP mode.
AUX Mode (AUX only)
The output is closed in controller AUX mode.
HRB Mode (CMB only)
The output is closed in controller HRB mode.
Controller mode
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...